Ok, so you have 250 changes you need to make, but ASA doesnt have a blank option in some of the selections i.e. MWI server, coverage paths, well i just found out that if you put "" in the field, it will blank it out.
Avaya drops wireless headsets
Avaya voice gear will be available through certified vendor partners
By Tim Greene, Network World
December 21, 2009 03:44 PM ET
Avaya, which promotes itself as a software company, is trimming back even more on its line of hardware with the elimination of...
CM5.1.1
I have a user that would like to block a certain number from the PSTN, i know i can create a VDN & all that, but is there something new in 5.1.1 that would enable me at the trunk level to block a number from coming in?
OK, i have a client that has a G350, they have 3 CO lines local & would like when one of those numbers is called, it displays the caller id of who is calling them.
Sys Cust - Analog Trunk Incoming Call ID? y
TG is built as CO, loop-start, Using MM714. Receive Analog Incoming Call ID: bellcore...
WHY CAN'T THEY INCLUDE THE FIELD TO ALLOW ME TO CHANGE THE GROUP ON PAGE 3 OF A STATION!!!!!!
IP Phone Group ID:
Now i have to manually change 500 sets!!!
Has anyone ever seen an issue where as trying to login into a CM you get a 15 - 20 second delay before seeing the "Login:" prompt?
it's not the program i am using (ProComm) i took a laptop & went directly to the switch & i still get this delay.
ok here is what i found.
Running CM 4.0.1 with 96XX FW 2.0
Station A is call forwarded (off net on net, doesn't matter)
Station B receives a call (internal external, doesn't matter)
Station B transfers the call to Station A
Station B never gets the "complete" softkey.
i know there was a...
All,
i am running CM4.0.1.
if i have a brdg-appr on page 2 of the expansion module, how can i have the page switch when that line gets a call instead of the bell.
whats the latest verison of ASA, i have 4.0.12u1.0 but i notice that some of the station import columns are not there, i need to change about 100 stations to a new IP Phone Group ID: on page 3. my CM is 4.0.1
any ideas?
A client is asking me for the below info, what menus, commands would i do to get it?
Max ports used per day
Total Storage Hours/ used and free
Average mailbox message size per user
i have a CM4.0.1 & calls going over one of my circuits are now giving the below denial event when doing a list trace:
1193 Equipment congestion Switching equipment congestion.
See Cause Value 42 on page 163.
UID DIAG/LOC/CV
Cause Value 42
[0x2A/0xAA] -
Switching equipment congestion
The call...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.