Hi All, Hope your all well. Card in the option 11 cabinet seems ok. It is the light in the 81 that is flashing Tested Fiber (just light test) changed out MM Cords on both sides. Self test on card passed I am going to be driving for both cards. We dont have in stock. Just wanted to throw...
Hi all, I have a customer that is down hard I have all the CDs, keycodes bu,s and stuff I need to re image. I don't have that PCMCIA card. Tried to order from NT/Ayaya part is obsolete. Can I find the files on line? Does anyone have one for sale? Thanks in advance for any help possible...
call pilot is 5.0. and it is the 000000 mailbox #, just wanted to know if anybody could help before i have to contact Nortel...Thanks in advance..John
Cursed and Blessed is the day that we decided telcom would be our profession.
Hi all, quick run-down: BCM 450, all patched current, 3 pri cards and dsm 32 in main chas. 1 dsm 32 and 5 asm8 mbms in the expansion. switch does have Capacity Expansion Card. switch has every option known to mankind. icc, 20 ip phones, mix of 7324's, 7316's and 7316e's remote phones(ip...
Hi all, does anyone know how to master reset a DMC 80 or 320, the customer has changed the PW and he does not know what it is. I hope someone can help..John
Hi all, Option 81c has had Lightning issues in the past!!!
Problem: a certain shelf has analog w/ MW line cards that wont light the light on a 500 ser. telephone card works fine other than that. the card will work fine on other shelf, is this a bad shelf, ring gen power supply?