Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations biv343 on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: bija77
  • Content: Threads
  • Order by date
  1. bija77

    TSE 6.1 SP0 HF2 with One Box 5.1

    hi All, i upgraded the system from TSW to TSE ver 4.1 SP4 (Mx-one server and classic media gateway including LSU-E and IPLUs)and One Box 5.1 with SIP integration. and now i successfully upgraded the system to TSE ver 6.1 SP0 HF2, but i have a problem with the One Box as following: when I...
  2. bija77

    BMS stoped

    Dear All, i installed BMS and it was working good, but when the windows update the Framework to 4.0 version the BMS stoped. so when i run the BMS the BMS server window appear normally then Suddenly disappear. i tried to uninstall and re-install it but nothing happened, also i tried to install...
  3. bija77

    remote SIP extension

    dear all, - I’m using MX-ONE TSE V3.2, and X-Lite softphone. - All data network components are Cisco. - I have successfully registering the SIP extension remotely using the X-Lite softphone(at the internet), and when I make a call from or to the remote extension from or to any local extension...
  4. bija77

    Diavox

    Dear All, I have new installation for Winseries voice system (Diavox) on Windows 2003 server. The installation completed successfully, and regarding to the installation document I must install Dialogic Patches (service pack 1, feature pack 1, and service utility 66), but I have only the feature...
  5. bija77

    Fax over IP network

    dear all, The IP network has been installed successfully between MX-ONE TSW SP2 and BP V 8.0, and it works fine. But I’m facing a problem when I send fax from the MX side to the BP side. The parameters used for configure the two sites as following: MX-ONE SIDE:IPLU BPOS=1-0-30...
  6. bija77

    E&M Tie Line

    Dear all, I tried to install E&M Tie line between two MD110 BC9 exchanges using TLU-80 ROF 137 5406/1 R10B and its working good. And now the customer needs to bind the other sites. Is the TLU-80 ROF 137 5406/1 phased out or not? Can I use the new board (TLU-80 ROF 137 5406/11)? The systems were...
  7. bija77

    upgrade

    Dear all, I have to upgrade MD110 BC9 system to MX-ONE TSW. Note that the system was BC3 then upgraded to BC9. But please I need to know, what will happen if one of the magazines power board damaged (I mean (3LLO 1314267/1- BFB 101001/1- POU5V 131991/1A)) can we replace it with RG5DC or DC/DC...
  8. bija77

    Dialog 4224 operator

    can i use head set with dialog 4224? if yes what is the product code of the head set which i can use it? note that: we connect the dialog 4224 as an operator to MX-ONE TSW system.