i like to know how it works guys ,key 2 dn 3807 as it own voicemail box 3807 ... how are calls forwarded to that mailbox , tried removing it and putting in on and other tn , has scn and addind XMWK 7500 3807
did not work
REQ: prt
TYPE: tnb
TN 20 1 5 5
SPWD
DATE
PAGE
DES
DES 5094...
we had a huge storm here and we had alarm 42-0 on all sets but all is back to normal how do we clear that alarm from the displays ...i think it can be done from the attendant console if yes how ???
ty
guys
last week a programmed a ring group for the attendant and an assistant beside her, (ring group 001) that works fine but since then they have problems call forwarding their calls to another center after hours...they do *70 then the external nummber release button then night ....
thanx
guys!!!!!!!!!
at the hospital i work at ,we have a building wide intercom for emergencies dn40 that can be used from all phones, but sometimes users dial it by mistake or keep it off-hook ,i can go into ld 80 and do a trace ..but is there a way to send an alarm to the attendant console...
hi guys we are going to put a emergency buitton on each m2616 at one of our sites that has an option 11 ,it worked fineat another site that has an option 61 is there a cls missing or preventing it of working tried it on key 9 and 11 on this TN
thank you
DES 8900
TN 015 0 00 10
TYPE...
hi guys
we are trying to figure out how this ACD works this an acd number that forwards calls to another center there is a code 790 before the 9514xxxxxxx the number of the other center what does the 7990 means and where do you program that thank u
REQ: ****
OVL000
>ld 23
ACD000
MEM...
i guys
we are having a problem trying to add a mailbox to a user we get this message "another mailbox is using this extension as an extension dn" we have a mermail 12
this is the tnb of the user
TN 14 00
DATE
PAGE
DES
DES 2272
TN 014 0 00 00
TYPE 2616
CDEN 8D
CUST 0
AOM 0
FDN 7000...
hi guys
we tried to do a backup on a mermail that is on an option 11c the message erro we got was
Act: Refer to the Tape Error checklist
Des: Tape 1 > sense key: 6
15-40 7/18 09:51 Admin * 1 Null
Des: Backup error. Lookup return code in NTP SEERs. for F8...x...
i guys
i have a very noisy Nam power supply is there a generic Pc power supply i could replace it with, what kinda power rating ? and is it easy to replace for a Newb
ntb74ca-93
hi guys we have a option 61 with mermail version 12
is there a way for a user who is on the road to get is message notification by his pager ...i've done it on a nortsar before
thank u
i guys
i have to put a hotline key on about 80 phones m2008 and mostly m2616 is there an newbie user friendly script i could use do it all in one shot ... AND COULD U TACH STEP BY STEP HOW TO USE IT THANKS
Georges
hi guys !
I wanna remove hunting to VM to allow call waiting (cls cwa,swa.wta !!!) how can i remove the hunt to mermail ext 7500
>ld 20
PT0000
MARP NOT ACTIVATED
REQ: chg
TYPE: 500
MARP NOT ACTIVATED
TN 4 0 9 0
ECHG yes
ITEM hunt????what should i write here to remove
thank you
hi guys
we have an option 61 with mermail is there a way to direct connect to the application ...i know with a optin 11 you can do AX to get into it , we wanna get rid of all modems
and has any of you used lantronix devices serial to rj45 to they work well??
i guys i have a user that would like to have call waiting other users have it on their phones (m7208) ,when they have a second call coming it comes on their second intercom buttom
do not know how to program that
guys
at our it helpdesk the receptionist is swamped there is no calling queue or acd can i just lets saY her extension is 5092 can i hunt to 5093 then to 5094 and then voicemail of 5092 .....but 5093 and 5094 have their own voicemail i want a call coming from 5092 to bypass voicemail of...
guys
we wanna change the ups we are using is there a special procedure to shutdown system or just pulling the plug will do ? and how long should i wait to replug ???
hi guys
i have a small option 11 with only 7 tn's !!i'm trying to direct connect into it and when i do get in it i have "Mnemonic" written on the command line
this switch is tie lined to another switch
hi guys.....
at two of our health centers we wanna put an emergency button on all phones that dials to 450-xxx-xxxx extension (3333) how can i do it all in one shot
hi guys
i have a mics that has an extension that external callers can leave messages but not internal ones??? the phone is a m7100
thank you so much
georges
hi guys
i'm running out of analog tn's and i'm pretty sure i have lots of live extensions that are unused with no phones plugged in is there a way of knowing how to do that i read a post talking about a frame test !!! can u guys elaborate on that or other methods
thanks