Our PBX Meridian CS1000M
Version 3221
Release 400T
When set up call forward to external for DID line, the caller info show on the far end is the site primary info, instead of the actual caller.
Is the system able to send the original caller ID?
For the last 10 days, one of our PRI line has red alarm issue so frequently. Based on the history file, it just went up an down every few hours. See below.
I called the telco but they always said they reset the circuit and the service came back, but never fixed it 100%.
Any suggestions...
DID Range: 123-456-78xx (00~99)
extension range: 7800~7899
Here is the RDB and DID setting:
TYPE RDB
CUST 00
ROUT 1
DES
TKTP DID
M911_ANI NO
M911_TONE NO
NPID_TBL_NUM 0
SAT NO
RCLS EXT
VTRK NO
NODE
DTRK YES
BRIP NO
DGTP PRI
ISDN YES
MODE PRA
IFC NI2
CBCR NO...
3 sites:
Site A: Cisco CM 4.2 (212-555-75XX)
Site B: Nortel 81C (212-555-79XX)
Site C: AVAYA (305-666-45XX)
History:
Site A and B are in the same building, connected via PRI link, routing plan had been configured, user can dial to each other directly by 4 digits extension (75XX and 79XX)...
I have about 100 numbers/number ranges needs to be input as ARRN in one SPN, is it possible?
ie.
SPN 212
RLI 1
ARRN 654 ARLI 2
ARRN 6543 ARLI 2
ARRN 6544 ARLI 2
ARRN 6543210 ARLI 2
...
We have CS1000 connected to far end PBX via PRI linke (Rout 30), each side dials to other side by entering 4 digits extension number.
Now we plan to route all outbound calls to the far end pbx to using their trunks to call outside.
I configured this in CS1000, but it failed and gave me fast busy...
NYC: Nortel CS1000 using PRI link connected to AVAYA PBX A, each side can dial to other end directly by extension#.
DC: AVAYA PBX B
AVAYA PBX A&B connected via IP trunk, A had been configured to using B’s outbound trunk when dial DC area numbers, 202 etc.
We plan to configure the PBX to also...
Nortel CS1000, 1 T1 PRI trunk (RDB 1) carries outbound call. Now we plan to set up 2nd T1 trunk (RDB 2), and we want to have all outbound calls to 404-335-xxxx and 404-661-xxxx to be routed to 2nd T1 trunk.
How to change the ESN setting to have this feature work?
Currently setting:
AC1: 9
SPN...
As I know, changing in LD10 for telephone will disconnect the call, but I'm not sure if I change the setting in LD16 RDB will also disconnect all chanells in that route group?
Thanks for your confirmation!
If I have 2 receptionists works on different floors. I want to set up each receptionist with a M2250 attendant console. The company has several primary phone numbers, so during the daytime, all incoming calls will be distribute to 2 receptionists by the number.
Here is the setting. Is it...
We have 2 T1 PRI lines. Since last week, one of the lines went down frequently by red alarm. I called carrier and opened a ticket. But the issue keeps happen even they claimed to replace the circuit.
.stat 4
PRI* TRK LOOP 4 - ENBL
FFMT/LCMT/YALMT: ESF/B8Z/FDL
TRACKING
SERVICE RESTORE...
I have a T1 which using for outbound calls. Recently, I just realize that our caller ID doesn’t show correctly on some carrier like Tmobile wireless.
For example, in my PBX setting, 212-9xx-1000 should show as caller ID on far side.
It works on the below far side users.
646-xxx-6210 Verizon...
Hi all,
If we have a non-published service activated on the T1 PRI service provider, then even we configure the PBX by sneding out caller ID, there will still show "unknown number" or "private" on far end phone?
Am I right?
Thanks
Meridian 61c, DID trunk
sometimes the incoming call shows the caller ID as "54_1""54_2""54_3", etc.
when I trace the call, the log show as below:
.trac 12 0 5 12
TN 012 0 05 12
KEY 0 SCR MARP ACTIVATED
ORIG 004 01 DID RMBR 10 1
TERM DN 3523
TDTN 10 SLOT 17 PTY SLOT 17...
For example, I want to know how many active digital phone sets within the meridian PBX.
By LD32, using "LIDL", I can list out all ports, but I have to calculate it. Is there a simple way? I just need to know the number.
When I tried to change a hot line number, it give me the err code as below, anything wrong?
REQ: chg
TYPE: 500
TN 28 1 6 10
ECHG yes
ITEM ftr hot d 4 5202
SCH5537
FTR SCH0355
FTR SCH0355
FTR SCH0355
FTR
SCH0355
FTR
ITEM ****
Original setting:
TN...
We have a plan to implement 6 digits speed dialing in Headquarter.
Description: Headquarter in NYC, 3 branch offices in ATL, LA and Chicago.
ATL office DID number range 404-123-xxxx
LA office DID number range 310-456-xxxx
Chicago office DID number range 773-789-xxxx
NYC user can dial 41-xxxx...
Sorry for open a new post, but after several days, still confused about the sequence.
Here is my question again: 2 columns, 8 shelves, AC power in each shelf, 2 power break at the back bottom of each column
[ IPE ] [ IPE ]
[ CPU ] [ IPE ]
[ CPU ] [ NET ]
[ MM ] [ IPE ]
1.When I turn down the...
For SOME reason, SOMEONE wants to test the power system and reliability in the data center. So we are infirmed to shut down our 81C completely during that incoming day.
I need suggestions to help me prepare this event, every detail will be helpful. Also, I’ll ask our vendor to come in that day...