Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: alecra
  • Content: Threads
  • Order by date
  1. alecra

    Moving a 2250 Pc Console

    Hi, Were currently trying to move a 2250 PC Based op console. Nothing new, same type of cabling, and basically it wont work. It worked fine where it was. Approx 600ft away. We have verified the cable tests good, tried a few different pairs anyway. It works perfect straight off the MDF, then...
  2. alecra

    "H" on caller display

    Hi, We have a 61c and 81c, connected via TYPE:atvn TRK:pri Trouble is our voicemail system is off the 81c and calls coming from the 61c have a "H" in from of the caller id so the voicemail doesnt know what to do with it. Ive changed CLS on a 500 set on the 61c to CLBD and it works fine as...
  3. alecra

    Option 11 Group call

    Hi, Ive been reading about the group call feature on here. I have one set up on our 81c with 17 members (I Think) I assumed id be able to do the same on our 11c but alas, no. It says the max is 6. IS there anyway to change this? Were kinda short of CO pairs to some locations. Thanks!
  4. alecra

    Intercom

    Hi, Anyone know a way of using the DIG feature to page multiple sets at once? I can only figure it to go set to set, but would like to broadcast voice over about 20 sets. Any ideas? Thanks
  5. alecra

    Interloop test start?

    Hi, Our 81C keeps running through an INterloop test? Not sure why, we've had no copmplaints, but its constantly cycling through tests and switching cores. Both cores look healthy. Any ideas?? Thanks!
  6. alecra

    Cant break dialtone

    Were having a problem in that we cant break dial tone on allot of POTs. Everything else is fine. The POTs are on different loops / shelfs. The switch health count is correct. Any ideas? Thanks
  7. alecra

    Voicemail forwarding problem.

    Hi, We are having trouble with voicemail forwarding from switch A (61C) to switch B (81C). All vocie calls are fine but when a user doesnt answer or is busy the call will hunt/fdn to the voicemail pilot number but seems to be missing whatever flag tells the VMX its a forwaded call so it just...
  8. alecra

    Changing login banner

    Hi, Does anyone know how to change the standard "WARNING: THE PROGRAMS AND DATA STORED IN THIS SYSTEM ARE LICENSED TO OR ARE THE PROPERTY OF NORTEL NETWORKS".......ECT ECt" We needd to change it to a standard site warning banner. Thanks
  9. alecra

    LHK on a 2616

    Hi, Has anyone ever had a lhk of higher than 6? I have set the lhk to 9 but it wont hunt past the programme key (7). In procomm key 7 is blank but it wont let me assign anything to it. Any help greatly appreciated.