We have installed one CP 202i on CS1000E rls6.0.Call pilot is working ok but ACD(CS1000E0 channels are getting disabled in every 8 to 10 hours and CAll pilot channels are showing Remote off duty.Please help
Hi, recently we have upgraded one nortel 11C rls 4.5 system to CS1000E rls 6.0.
After upgradattion if m2250 console makes a conference call the other parties in conference are getting beep tone intermittenetly.If console comes out from the conference call then there is no beep tone in running...
Hi John,
I have gone through the script you have send and it really worked at thread798-1216430. However,what I have understood is it only works when we try to login to system . Its not an automated process. I have remote sites unmanned how can we implement this So that in daily inter val the...
Dear Friends,
In one of my site I have Cs1000T and CS1000E . CS 1000T is having Euro ISDN PRI with one of the service provider. While making calls from Ip phones registered in 1000T (for test)I can pass on my 4 digits of extension no which in returne is used by the service provider to send the...
Hi there ,
One of my site got a M3904 as TDM phones and 1140E as IP phones togather in the same system. But if a user is busy on one line of he/she recieves 2nd call ,the CLI of the 2nd call doesnt appear on the display.
But for M3904 it does so.
Any help would be appreciated.
1140E firmware...
Hi Guys,
I have got something to share that I have CS1000s which has got a tie with Siemens realities switches with a DPNSS trunk.
But when any ext of nortel calls Siemens ext the name display doesnt happens and vise versa.
Any thing which can be done anybody face like this.
Will be of gr8...
Hi,
I have got an 11C with rls 4.5 and MC32 card with Ipline 4.50.88 on it. The site has got 4 no of i2004 Ph2 phone with D9F firmware on it. But they complains that compare to digital or analog phone the voice quality is very quite at IP phones while making an outgoing call thru DASS PRI or a...
Can anybody ever connected public address equipment to Meridian for mass announcement from telephone via some accesscode .
Can it be connected to COT card.
Please advise wht hardware may be required for this kind of an arrange ment.
DAS1512
Our office want to have two night service options
1. NS1 this for Monday to friday ( Night DN 1)
2. NS2 this is for week ends and office closer days like holidays.(Night DN 2)
System details : Meridian 1 Option 11 Rls 21.54 ver 1411
Also this is to confirm that the system has got ENS package...
Hi frens,
Just a quick question I have newly installed CC6 CCMS CCMA and I could able to login and do all the admin work from the CC6.0 CLAN . But If i try to access the CCMA from a different VLAN my connection to the CCMS shows orange in color i.e client unable to connect to CCMS.
But I can...
Hi guys,
I have Callpilot 2.02 with a application created in app builder for welcome greetings , also I have XCOT-I card installed .If calls landing on COT cct with ATDN as the application DN created in builder, the caller cannot hear the welcome greetings but on the contrary they hear (If you...
Hi
Guys
Can we take CDR dump from J25 port set as CPSI or on the LAN to some pC connected through TTY port set as PTY .
Hope I could able to put my question correctly.
Regards
DAS1512
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.