Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: fhweich
  • Content: Threads
  • Order by date
  1. fhweich

    mitel individual trunk access on PRI

    Hi, I have a strange situation, We have 5 Pri's (3 on one controller, 2 on another) When I do individual trunk access I can pick up trunks 1, 2, 3 on each PRI but none of the rest. PRI's all up(green) Trunk status all Idle All use same COS and COR ACC code - *#2 e.g. *#2 0001 083XXXXXXX = OK...
  2. fhweich

    Micollab advance UM voicemail BLF control

    Good day I need help locating the reason voicemail and Advance UM integration stopped working. Configuration: Micollab 6.0.1.121.0 NuPoint UM 17.1.0.1.01 Mitel clustered environment (23 controllers, 5 local) MAPI gateway (ver 10.0.0.11) on Windows 2012 R2 server Exchange 2010 Hub server. Voice...
  3. fhweich

    Locate number

    Hi All Mitel 3300 member of cluster When dialling the feature access code *2 to pickup ringing ext there is a delay of a few seconds. DGT trace indicate more digits needed to route - thus indicating a number in system/cluster = *2??? How can one locate the number and location? eg *21,*235*...
  4. fhweich

    call forward invalid

    thread1329-1585347 Scenario and problem solving attempt same as in referenced thread. Can not find the solution though.
  5. fhweich

    SIP Client oneway speach

    Mitel 3300 with MCD 4.2 HTC with SIP client software (tested 2) Internal calls sip to 5312 = OK External calls from/to sip client = oneway speach No 5312 phones have problems with external or internal calls. What/where could the problem be?
  6. fhweich

    MLAA to ACD no interflow

    Mitel 3300 with MCD4.2 Programed below call flow 1) Inbound call to ACD path -> play RAD -> system MOH or tenant MOH -> interflow to Switchboard. 2) Inbound call to MLAA -> option 2 -> ACD path -> play RAD -> system MOH or tenant MOH -> interflow to Switchboard. Same ACD path used 1 work...
  7. fhweich

    SIP trunk calls drop

    Hi, I'm having calls drop on a sip trunk. CCS trace: 14:52:28 RIL DPN PEER issip 1231 10 CCM *50*0833266782# 14:53:33 RIL DPN PEER NIL_PEER_ 1231 F CRM/CIM ;30;*166*1 2 3 4# 14:53:58 ROL DPN PEER issip 1232 27 ISRM_I Where is this call...
  8. fhweich

    CX "blown" analog boards

    Hi all. I've had to replace 5 sets of analog main and options boards on a CX system. System earthed, on UPS, Lightning protection on trunks and extensions. Heavy lightning area, but had the LP modules tested and OK. Are there any posability that the boards could be damaged from the systen side...
  9. fhweich

    3300 CX Analog board relay

    Where can i find programing detail, operating detail on the the 3300 CX/CXi analog board relay

Part and Inventory Search

Back
Top