  1. illios

    hd and mo problem hipath 4000

    I have a hipath 4000 v1 which I suspect that the hd and mo no longer works despite them being active act-dssm 1 and 6 act-dssm 1 generates a dscr error h 2B and act-dssm 6 generates no media both disks are mounted on the same board the system works correctly but I have no access to comwin I...
  2. illios

    Interconnect hipath 4000 and omnipcx entreprise

    We have a hipath 4000 V1 with a DUIN2 Board we want trunking with alcatel omnipcx entreprise T2 interface Witch protocol must be used and help me Who config diun2 card step by step Thanks
  3. illios

    hipath4000 we can't acces to mod drive

    Dears Hi, we have a hipath4000 v1 and we have a problem to acces to mo drive witch contain a backup system when we try to activate the drive we have this ACTIVATE-DSSM:UNIT=A1,CNO=6; H500: AMO DSSM STARTED F22: DEVICE <:A1H61:> IS NOT ACTIVATED BECAUSE OF DSCR ERROR H'2D a DDSM display ...
  4. illios

    CLIP DISPLAYED

    WE HAVE A HIPATH 4000 V1 Connected with analogic line with clip option to post office how must we configure it to dislpay the incomming call the PO STATION?
  5. illios

    hipath 4000 missed call undislpayed

    we have hipath 4000 v1 which run normally until yesterday . we have changed the cordless data base (after a breakdown ) with CATtool ver 2.3 and the system run correctly unless the mailphone (missed call) didn't appear in the cordless mobile (SL1). the parametre DIGNODIS=N in the SBCSU amo is...
  6. illios

    CATtool

    hi i have hipath 4000 v.01 to administrate cordless station , I instal CATtool version 7.0.30 my problem is that this version seem incompatible with my hipath , many amo command don't work (not present in hard disk ) like amo slcb , zande ... can any one help me to find another version CATtool...
  7. illios

    erreur amo zande

    hi to generate data from my hipath 4000 to CAT tool we have this erreur: display-zande:typealldata; M13 VALUE not within admissible range the amo zande display the same erreur with comwin program can any one help me ?
  8. illios

    can any one help me to find the ECI

    can any one help me to find the ECI ID for my hipath 4000 with amo command thanks
  9. illios

    cordless administration tool v 2.3.2

    can any main help me to get the soft CAT v 2.3.2 to administrate my hipath 4k ? thank you
  10. illios

    can't connect with hipath 4000 ppp dial

    i have a hipath 4000 v2 pabx in office , my problem is that we must have a PC outside the site to administrate the hipath , i have use a modem v24 dial up connection with a rtcp line but can't connect with the equipement , i heard the ring during the connection but nothing else remarque : i...
  11. illios

    hipath assistant expert ereur

    we use hipath 4000 and untill his installation we have the same problem with the assistant ; when we logon an error is generate : erreur 103 ( grave erreur dans CORBA, selection/creation de IOR_object ) have anybody meet this error ?