  1. amitde

    M2250 Console-conference

    Hi, I have 4 console in my sites.When trying to make conference, i am able to get up to 2 people and then when i hit the conference button it disconnects the call.Transfer is working fine. Only the problem with Conference.Can anyone help me out. >ld 21 PT1000 REQ: prt TYPE: att TYPE ATT_DATA...
  2. amitde

    BCM PRI connection

    Can some one guide me on how to connect a PABX to BCM400 through PRI? I've a v.32 card for the BCM. Thanks, Amit
  3. amitde

    VM issue

    ext 4608: the first call goes to 4608 when busy it goes to voicemail, if a third calls comes in the call does not go to voicemail, it goes to the revert DN of the mailbox. This occurs when the second call is currently leaving a voicemail. Any help?
  4. amitde

    MWI on 3904 sets

    Hi there, I've this unusual problem. Follows.... 3 extensions MWLamp is constantly on, swapped phone sets, removed mwa key, re-configured extensions, but no good. Sending across the configs.. ==================== x1021 follows... ==================== DN 1021 CPND CPND_LANG...
  5. amitde

    Remote INI

    Could someone help me with the commands for giving an INI and SYSLOAD to small and large systems? Thanks in advance, Amit De
  6. amitde

    outgoing calls blocked

    extension can receive internal and external calls bit can't make outgoing calls [internal/external]. Its an analog extension. Thanks, AD
  7. amitde

    81c INI issue

    Hi following I got from the pdt logs.... 213 :(28/4/06 17:17:56.444) BERR705 EXC 1: Bus Error in Task "tSL1" (0x8d10fe0) SR=0x3000, PC=0x5017aea, Addr=0x13122f80, SSW=0x850010 214 :(28/4/06 17:17:56.449) BERR700 EXCH: Threshold exceeded; vector=0x2, PC=0x5017aea, fault...
  8. amitde

    unknown errors on 11c mini

    Hi, I am getting these continous unknown errors on my 11c mini rls 4t.... APR 20 11:02:05 VGW: Warning channel 8 received invalid User Input message 12 from Call Server Any help????? Thanks, AD
  9. amitde

    Time on switch

    Hi, Time on 11c rls 3 is gaining clock. I wanted to know the time adjustment feature in ld 2. Wanted to know the usage along with the idle parameters[adjustment 1-60 seconds] for printing and setting it. Also would lamp audit help in this regard? Thanks, Amit De
  10. amitde

    BUG messages.

    Hi, System is 1000M, rls 4. Complaints of echo, static, and silent calls in the calls centre on network calls. Site has network SCCS too. Getting the following BUG messages in 2 of their sites.... BUG9801 BUG9801 : 14 51 28 15 2 1 1 1 1 1 64 - 4 0 BUG9801 + 006C3F44 08C6D3FD 00DE1B1E...
  11. amitde

    PDT in 11e Rls 19

    How do I upload patches in 11e rls 20 or 19. I find there is no pdt or ld 143. Any help? Thanks, Amit De
  12. amitde

    Callback DN

    Whats id the Callback number dn used for in call pilot? Thanks, Amit
  13. amitde

    Call back number

    What is the callback Number DN used for in Call Pilot? Thanks, Amit De
  14. amitde

    Firmware Issue

    Hi, Is there a way to list/print the date and time when the firmware for a list 39xx phones were done? Its 61c. Thanks, Amit
  15. amitde

    tty port issue

    Hi, I am connecting to the pabx using modem. Modem connection gets established successfully. But when logining to the pabx, it throws junk. Tried with different bps and parity, but no good. Is there a way out? System is 11c. Thanks, Amit
  16. amitde

    Remedy v6.3 issue

    Hi, I've a issue with my Remedy client. Whenever I login using my client to Remdey server, it should ideally open my homepag with hyperlinks on the left hand side to go to various forms. But since quite some time, whenever I login, I get this error msg: "error generating apllication field list...
  17. amitde

    Certification guide

    Hi, Looking for exam guide documents for "Converged IP Networks", exam code: 920-804. Old exam code was 920-802. Checked in Nortel site, couldn't find any. If someone could help me find the docs. Thanks, Amit
  18. amitde

    Speed call help

    Hi folks, Can anybody explain me the difference between system speed call and user speed call? Also the difference between SSU, SSC, SCU and SCC? Thanks, Amit
  19. amitde

    11e gaining clock too fast

    Hi, System is 11e Rls 21.23+ Its gaining clock by 10 mins every 30 seconds. Please help. Thanks, Amit
  20. amitde

    1800 number issue

    Hi, 1800 numbers are not pulsing out properly on COT trunks. Due to this reason, getting carrier message, "number u've dialled cannot be connected, please check the number you've dialled." 11c, rls 25.30 Thanks, Amit De