Today i've received this eMail from Nortel:
Dear Stefan BXXXXX,
This email is to notify you of a change in status of the Request that you submitted on Jun 13 2006 regarding Business Communications Manager. The first 500 characters of the Request were: 'The DN renumber wizard has been removed...
Do not apply CORE patch 7.14 (BCM 3.7) as long as you wish to receive digits starting with "0" in german profile.
You will not be able to receive digit "0" over PRI or BRI trunk for your switchboard anymore!!!
Hello world :-)
Since BCM 4.0 the BCM recognizes the BCM model type (200 or 400) by reading the model-values from the system BIOS.
This will run you into problems if you're running your BCM200 with a BCM400 motherboard and you would like to upgrade to 4.0.
It is possible to change the BIOS...
Anyone ever networked two BCMs using BRI and EURO-ISDN or QSIG?
When setting one endpoint to T and the other to S it works. But i need both ends to have T because i want to route whole number-blocks, not just only 8 numbers (with S)
I'm trying to connect a fax-server (ferrari fax) using a OfficeMaster Card (by ferarri electronics) to a BCM BRI module using QSIG.
The card supports QSIG and PtP. The Loop on the BRI is set to T/QSIG.
The Link won't come up.
anyone ever tried that before???
Exchanging BFTs (Motherboards) between a BCM200 and BCM400 works fine if you're NOT running BCM4.0!
Upgrading to BCM4.0 will fail if you're running a BCM200 with BCM400 BFT and vice versa.
I've created my own BCM 3.7 patches today. Find them at: ftp://ftp.etkn.de/pub/bcm
Description:
BCM_370.254_ENABLEVNC.0.1.exe
Enables the BCM VNC Access
BCM_370.255_CUMULATIVE.99.ETK1.exe
Customized Cumulative Patch. Includes all available BCM 3.7 Patches (as of April the 6th, 2006)
Please...