Hello,
When an extension calls a mobile phone the CLI of the extension is displayed.
If an extension calls anopther extension, but has a divert to mobile phone, then the CLI of the main number is displayed and not the CLI of either extension.
Can someone explain why this is?
Thank you :o)
Hi,
My customer has some ELU31/1 cards (R2C) for use in a /50 cabinet.
There will be three cards, all in the same magazine. What do I need to do for sync and bus?
Many thanks
I'm being an idiot here, I'm sure.
Why can't I get a follow me onto and ADN?
Handset 7967, it "owns" the ADN 1556 which I want to forward to voicemail 1600.
I tried *2*1556*1600# and it doesn't work.
Any ideas please?
I'm attempting to overcome a problem on a customer site by using an MD-Evo as a gateway between ISDN2 and SIP.
We have an MX Ts3.2 that is licensed for a SIP trunk. We have 4 incoming ISDN2 ircuits carrying DDI.
My plan is to put the Evo in between to covert and transit the calls to and...
I'm having a massive problem with the buttons on a 4425 handset.
The programmed buttons for Call Pickup and Message Waiting do not appear to be working.
How do they communicate with the ESU (TSE ver 3.2 sp2)? Which ports do they use?
I am struggling here and have an increasingly disappointed...
All extensions are H.323 IP on Ericsson 4425 handsets. System is TSE 3.2 sp2.
We have a main number 4300 which is going to reception (normal handset). We need it so that when she's busy or doesn't answer the calls roll over to a group of users (we have an analogue extension monitored by 3...
Hi there,
I am building a TSE 3.2 over two sites. We are using IP handsets throughout both sites and there is a 10 meg internet connection (VPN between sites).
Are there any considerations I need to make? Do I need different config files for each site?
I'd appreciate all advice and help...
Hello,
I'm trying to set up a small site with TLU79's used as the only means of inbound/outbound with DDI.
I currently have the parameters:
<rodap:rou=all;
ROUTE DATA
ROU TYPE VARC VARI VARO FILTER
40 SL60 H'00000304 H'00000000 H'44410000 NO
END...
Hi there,
I have found an old AAU card and have configured it for IP. I have trouble when using tncom mml though.
I initiate the tncom and get the correct prompt from the Md110, but when I put in the username I get FAULTY INPUT DATA and it asks again for username. I cannot see why this is...
Hi There,
We have started to support a number of telephone exchanges running an embedded Linux server (SUSE sles 10)
The embedded server motherboard is very basic and only has 2 NIC's, 2 USB ports, video port and a serial port.
As these units are running on customer LAN's we have restricted...
I have an NIU2 with no flash disk running in an empty lab system. I try to get on to NIUX with MDUSER and HELP but it says INVALID LOGIN :o(
Not sure where the NIU2 came from, I want to find the IPA number and ethernet parameters.
Any ideas? Has it held onto whatever login details were set...
We have a customer with existing instance of CCM, DNA and SQL running on the same server. Now the server is running badly and the customer wants to build a new server for CCM and DNA and use an already existing SQL server in the same domain.
The first part of the migration is to install CCM on...
Hi,
I have our in house test system, open license, and want to start DECT function.
I have installed 1 x ELU31 and wired out to the frame. I have installed TSR 901 1234 cable between the sync Rx and Tx on the same board. I have set SARI to 12345678. I have initiated CXCFI and CXRFI.
I...
Hi, sorry for the rudeness of my title.
I have livened up 2 ISDN30 circuits, in the same route. The service provider show all outgoing calls on these circuits with the main billing number, but I need to change that so that the switchboard number is sent out, from all extensions.
I cannot...
Hi,
I have a customer that since an outage of 2meg leased lines at the weekend, cannot access VM from a site.
Lim 1 has external VM over 8 analogue line and ICU link.
Lim 2 had failure of 2meg lease line
Lim 3 connected by lease line, no failure.
Now Lim2 users cannot access VM, it just...
Hi,
I am trying to set up an external follow me for a hunt group.
Group number is 1444, spare voice number is 1924, external divert position is cell phone.
I have tried setting 1924 as an abb dial to cell phone, then *24*1444*1924# but that didn't work.
I have tried setting 1924 as a generic...
Hi :o)
Can anyone tell me the difference between an ICU card and an ICU2?
Also, what is the correct cable to use for voicemail application? I already have the v24 filterboxes but must order some cables. I have TSR 902 0438 cables but they are for SIU interface, are these different to ICU...
Hi,
We have a site to upgrade from BC8 to BC12. it has 4 LIMS, 1 on the main site and three seperate remote sites.
The remote sites all use very old multiplexers. For some reason when we try to reload the system from the NIU2 with BC12 software two of the LIMs do not load, they see the GSM...
How many characters are allowed? It seems to be less than the 3213's!!!
On a 3213 name comes up as M Pollington
On a 4225 name comes up as Pollington
Not a major problem, but annoying to my users :o(