Hi I think this is a logn shot, but wonder if anyone can help. A Nortel BCM50b has 2 BRI ISDN ports. Does the unit have the harware also to support an anaogue trunk. Ie can one of the ISDN ports be disused and the system configured to use an analogue trunk connected via the 25 pair...
Has anyone got Business Element Manager running successfully on Windows 10?
When I try nothing happens.
I have Java loaded, with MD5 enabled again (via editing java.security).
In a network of say 2 BCM50's connected by H323 if the private DN length is 4 digits this works fine for set to set dialling between the systems. However if BCM B has no PSTN trunks and I want it to have access to the trunks on BCM A. I can setup a remote package etc.
However how to I allow...
Hi
In a network of BCM 50's (all on Rel 6 and patched) where H323 is used to network the systems together is there a way to suppress the H displayed on a destination sets display when a call is received?
UDP is being used as the network type.
I know on the larger CS1000's there was a plugin...
Soon I will need to network two BCM 50's together.
Is the recommendation in this instance to switch them to 4 digit extension numbers and have one of them in the 2xxx range and the other 3xxx ?
or is it ok to keep them at 3 digit extensions?
Also I will want the capability of making a call...
We have a CS1000M (option 81C derived) running 5.5 software it still has an old ITG trunk card providing H323 trunks between other CS1000s. Old yes but it works.
I need to downlaod a new dialplan to the card but everytime I try to transmit a dialplan from TM 4.0 it fails.
I have a telnet...
I have a Cs100M (option 81 derived) running 5.5 software.
Currently it has SIP trunks defined between it & an Avaya CM
I'd like to also have a Polycom video bridge connect to it via SIP but am told that under 5.5 the SIP trunks could be to one endpoint only. Is this right?
anyway to get it...
Still waiting for Avaya to fix access now patches have moved out of ESPL.
Can anyone tell me the version of latest Rel 6 BCM 50 patches both SU & Desktop please?
I am trying to setup a number of SIP trunks from Draytel on a BCM 50 R6.
It's working fine and I can make & receive calls, however as I am adding child accounts to the SIP parent I am finding conflicts when defining the received numbers. The BCM will not allow a received number to start with...
Now that Avaya have moved patches etc around they are still struggling to get my access working, which worked just fine on ESPL. is SU-017 still the most recent for BCM 50 R6?
Hi
Has anyone got a BCM working with Draytel SIP trunks?
I have been trying and managed to get the BCM registered with draytel. I have setup a route and routing digit.
Using BCM Monitor I can see my call going out over the IP trunk correctly but then get an error display on the set - Temp...
Hi I need to FTP a keycode file to a CS1000M system that is based on CP II processors with floppy drives.
I have totally forgotten the designator for the floppy drive, as it was years since I worked on a floppy based system. I am far more used to /rmd for the later series machines.
Can...
Does anyone know if there is a serial port lurking inside a BCM 50?
There is an 8 pin header labelled J9 that is not unlike some serial port connectors on a PC motherboard.
If this is a serial port does anyone have the pinouts? It could be useful for troubleshooting bootup problems potentially.
I have seen reference here to people successfully booting a BCM 50 from an Solid state disk.
I tried this with a Kingston 64 GB, an SSD NOW V series drive. However the BCM wouldn't even begin to boot from it.
Can anyone advise of a specific make/model of SSD that is known to work?
Thanks
Clive
Hi,
This is a qeustion around a BCM 50 runnign Rel 6.0 software. An expansion chassis is needed on this system to accommodate a DSM16+ module.
Could this be installed some distance from the main chassis via a longer CAT 6 interconnect cable?
All those I have seen so far have a short cable...
I see COMBO-33 is now included in BCM 50 rel 6 SU7. Applying that does not give me the FEPS problem I had with COMBO-33 on it's own.
This contains a fix :-
Analog trunk lockup for UK market profile
An enhancement which allows the end user to set the disconnect supervision detection time...
Has anyone tried the COMBO-33 patch recently released for BCM 50 rel 6? I am interested in the Dosconnect timer for analog trunks.
I have a feeling that parameter was there before but not working correctly. As I have a system having issues with disconnect timers on analog trunks I have tried...
In our CDR output from a CS1000M we are seeing the ACD Position ID as the source of outbound calls from an ACD set.
Is there a configuration change that can be made to have the true Key 1 DN (on which the outbound call is made) appear as the source of the call in CDR output?
In preparation for a software upgrade we are looking to upgrade the firmware on a number of 3900 series sets.
I see 094 is available for ome of the sets but the link to download on espl isn't 'active' for those sets, yet the 093 version is. Does anyone know if the 0.94 releases for the 3904 &...
I have a remote CS1000M running 4.5 software. I need to load a patch - previously I woudl ftp to the system using teh CPSID account and standard password. That no longer seems to work I have Level 2 access to the switch so tried a standard level 2 account - still can't login via ftp. I...