  1. firenut1

    SIP TRUNK set up

    Has anyone out their set up sip trunks with clearfly its my first time any help will be greatly appreciated. thx
  2. firenut1

    Call Pilot 150 3.1

    Any help will be great. thx, Access Error: Data follows when trying to obtain /Voicemail-cgi-bin/F983Wui.exe?SecCon=myRmi3KRLlXphX9k1rim_eAar0mtZRnaimMmmmmmmmyhk3&AppCon=mmUmi3KRxmmmmmmmmyhV5X Form didn't call websDone does anyone know how I can fix this.
  3. firenut1

    Unified Messaging call Pilot 100

    Ok,so i follow the instruction to intall um on a pc but no icon or anything shows up on outlook. Does anyone know if Micosoft outlook 2010 is compatible with UM the CD i have is from call pilot 3.1 rls if someone can just point me in the right direction. thx MICS 7.1 CP 100 rls.3.1...
  4. firenut1

    BCM 400 site to site BCM50

    Ok, Guys Here is my question I have two BCM via t1 E&M everything seems to be working well. I can do seamless calling from sight to sight and point DID from site A to site B. But here is the question can I transfer calls to site B Via the autoattendant without having to purchase MCDN key codes...
  5. firenut1

    Old DID cards

    Is their a campatebility Issue with the old DID cards 6.1 software on a MICS.
  6. firenut1

    MICS 7.1 Question

    When setting up a system with 2 T1's is it require to have XC software and also two combo cards. If any one has the spec please let me know. thnx.
  7. firenut1

    BCM 450 issue

    I have a Hunt group build but after a while the group goes busy and the hunt group stops working. Pls Help
  8. firenut1

    BCM 450 issue

    Ok here is the problem Our extensions that are programmed for more than one line coming into it are showing “line in use” just as extension 219 was doing in the business office. Could you please find out why this is happening and what I need to do to eliminate this issue. Please let me know as...
  9. firenut1

    BCM 50 RCC error

    the Message is this In the Systen info section. contact center status:Cannot connect to DB those anyone have any Idea what this means? Pls. Help thx.
  10. firenut1

    Two MICS 7.1xc tie together same location

    I have to MICS tie together via T1 card one has a call pilot 150 3.1 and the other doesn't but they would to have centralized voicemail the question after reading the manuals is do I still need pri keycodes to make this happend and a networking keycode as well for the call pilot, I do have the...
  11. firenut1

    BCM 400 Question

    How many T1's can the BCM 400 Handle or what is the capacity.
  12. firenut1

    BST DOOR PHONE ON 6.1/7.1

    ok here is the issue that i'am having everything seems to be working right but the only issue is i can't hear the the person outside at the door. door phone ext 224 phantom dn 235 on ext 221,222,223 answer dn 235 dn 235 has (2) intercom / Prime line ICM capabilities/ handsfree set to...
  13. firenut1

    point to point programming on two MICS

    Does anyone out their have the thread for site to site with PRI on two MICS. Please Help, Thaks all
  14. firenut1

    Call Pilot 3.1 Issue with call center

    Has anyone run into this problem were u set up call center all the extension log in they receive the calls the way they need to but the strange thing is they cannot call out or call another extension until they log off then they can call out or call another ext.
  15. firenut1

    Call Pilot 3.1 Issue

    Does anyone out their knthe now if their is an issue with the callpilot 150 call reporting reports for the year 2009 becuse it doesn't show up on the call pilot.
  16. firenut1

    Compatability Chart

    I'am a nubee to the Partner systems and I'm wondering if any one out their know of some kind of Chart on how to find out what releases go with what. Please Help.
  17. firenut1

    Door Phone CICS 6.1

    o.k. here is the deal i Have a Vendor that is having an issue with a door phone on 6.1 he said he can't get F 9*4 to work and this is the second door phone we have send him does anyone know of any working issue with 6.1 and the door phone.
  18. firenut1

    Door phone on CICS 7.1

    Hey guys i need your help i have a door that sits on DN 25 and the ext that in rings to is DN 36 phantom vm with answer DN to ext 21,22,23,24 but it does not rings is their some in programming that i might be missing.
  19. firenut1

    NAM 4.0 to 4.1

    can i back up a 4.0 NAM and Restore it to a 4.1 NAM the customer wants to upgrade but keep all the Recordings.
  20. firenut1

    MICS 7.1 software issue

    Does anyone out there know if their some issue with 7.1 software, The problem that I'm having is that all the incoming calls ring at the prime set i have a T1 PRI all the DID's are set to private and all the channels i took off the prime set. Pls. Help thnx.