Had same trouble at site. Caller id did not work everytime.
Connected test switch at co on same trunks and it worked everytime. Connected caller id box ahead of system on site and received info everytime but not on BCM.
Finally found trouble with line, it was bridge tapped at ped.
Removed tap...