EB...
TAC never specifically asked about memory, but they have a "sho tech" from me. Also received and installed the WIC-1T card and got the same results. Gonna try router on another connectivity that doesn't use IDNX....beginning to think that might be problem. Thanks for the input.
Currently running a Cisco 2500 IOS 11.2(12) with one of the serial ports through an IDNX. I have four spare 2611's with WIC-2T cards & have been trying to get one of them up using IOS 12.3(6a). No problems loading the IOS and configuring the serial port. Local loopback on my IDNX shows both...
Ive done local and remote loopbacks with the following results:
Local Loop
sho int s0/0
Serial0/0 is up, line protocol is up (looped)
Hardware is PowerQUICC Serial
Internet address is 198.26.152.66/30
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
reliability 255/255, txload 1/255...
Currently running a 2500 with IOS 11.2 via an IDNX. Trying to get a 2611 with IOS 12.3(6a) online. Using a very basic config the serial port comes up and the protocol comes up. Line protocol stays up 27 seconds, down for 3 seconds etc.
Protocol stays up on local and remote loops. Using BGP...