Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. PEagle

    AccessPoint 1000 / Xedia reboots

    Hi All, 1. :-) I receive annousment from Lucent Techical Suport, that new version of APOS for models AP-1000 and AP-450 are available. The new version has number 2.5.0R.5.1 and has some fixes to memory management, especialy for forwarding profiles and ICMP redirection. In all previouse version...
  2. PEagle

    Access point Xedia /cbq

    First of all You must check, that some CBQ instance is stacked with network interface (WAN or Ethernet). You can do this by typing command: status. It should seems like: 1|slot.1.1 Tcom4 T1 Driver enabled up | 2|slot.1.1 cbq.1 enabled up |...
  3. PEagle

    Lucent CBX 500

    Hi, If cascade is not working, try to use NavisCore Operator password. It should work too. But remember, working in CBX via console is so risky. Much more better is to configure CBX and GX network using NaviseCore, which prepare special configuration files (for PROM) and can always...
  4. PEagle

    Lucent AP-1000

    For AP-450,1000 and 1500 is possible to clear community table and login to empty root account. Just connect some pc or terminal to serial/console port. Then reboot router (You don't remember password, so You must turn off/on power). Few seconds after reset on you screen you should see...
  5. PEagle

    AccessPoint 1000 / Xedia reboots

    It just means, that is not hardware failure. It can be system bug or system manufacure serial problem. In my opinion, errored configuration should not cause system reboot, becouse it potentialy can be very big security problem. Look at You mail box for my configs.
  6. PEagle

    AccessPoint 1000 / Xedia reboots

    It seems like some interoperability problem. What kind of system is on second site of Your FR link ? The 2.5.4.4 is available in Lucent as production release or hot-fix ? ps. W will start new 1500 box with 3.0.0R1 software. It is much more stable, but needs more memory (minimu 128MB to start...
  7. PEagle

    I lost P333R root´s password

    Hi, Connect PC or terminal to console port (serial port). Then enter login: root and magic password: ggdaseuaimhrke. After you login, immediate change password to new: set username root password new_password access-type admin It should work :-) Piotr
  8. PEagle

    AccessPoint 1000 / Xedia reboots

    I will resolve part of this problem. If You have any contact to Lucent support, try to request software revision 2.5.0R.3 for Your router. I also have newest hardware version (4.0). Lucent Access Point 1000 (hw: 4.0; sw: V2.5.0.R3 12/28/2001 11:21:33:00) This revision is not public available...
  9. PEagle

    AccessPoint 1000 / Xedia reboots

    Hi All, I get few uncontroled reboots of my AP-1000 router per day. I use maximum memory (256MB) and connection over 4xE1 to 2 upstream providers (2 full bgp peers with total 230 000 router prefixes and 40 000 paths). Each time router reboots i check console and see message: last reboot...