If you're talking of E1 ISDN. Make sure to test the facility, I mean the transmission medium. To test, put a loopback from the farend and a test equipment from your end, there should be a signal and no alarm this means that ur tranmission medium ok. Now check ur ISDN configuration like HDB3(PCM...
A multimeter will do. By testing if the tip and ring is grounded, has foreign battery, short or open. A tone tracer is also ok if you're tracing wires.
We are also a call with 300 seats were using a traditional telecommunication wherein we used a an International Private leased line E1 and compressed it to 4XE1 and the quality is good. we tried using a VOIP running over the IP cloud the first few calls were good because of lesser bandwidth...