Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Westi on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. it1234

    Info7.5 - Instances remain processing

    We run Seagate Info 7.5 in Win 2K server. Some of the reports remain "processing" for ever. When these reports are stopped and rescheduled, they complete within seconds! These are not even going to status "Not Responding". The MaxProcessingTime setting in the registry is 180...
  2. it1234

    Print Speed

    When the report is printed from ActiveX viewer, it prints upto 100 pages continuously and then slows down to print one page in every 7 seconds. The client machine is Windows 98 machine. Total number of pages in the report is 677. There is one conditionaly suppressed subreport in each page. (It...
  3. it1234

    Info Agent process terminates automatically

    The Info Agent process terminates automatically after the APS was started, even before any report is viewed using info viewer or web interface. Even if it is restarted, it terminates again by itself. Any suggestions? Thanks in advance.
  4. it1234

    Info Agent terminates automatically

    The Info Agent process terminates automatically after the APS was started, even before any report is viewed using info viewer or web interface. Even if it is restarted, it terminates again by itself. Any suggestions? Thanks in advance.
  5. it1234

    Distribute CR Informix 9 Driver

    To use the CR Informix 9 driver in the client machine, what files are to be copied to the Windows/System32 directory of the client machine?
  6. it1234

    Informix ODBC Driver 3.11 Unknown error -19820

    When a report with 5 tables is run using Informix ODBC driver ver.3.11, It flashes 'Unknown Error -19820'. This report works good with Crystal Informix ODBC Driver Ver 9. It seems the SQL generated with the Informix driver is not valid. Is there any fix so that I can use the Informix driver itself?
  7. it1234

    complicated crosstab situation

    Ken and Howard are right. There is NO WAY to use the cross tab in this case. If you still prefer to use the cross tab to get the advantages of it, the best way is to write a stored procedure to return one row for each product and count and use it in the report istead of reading directly from the...
  8. it1234

    Third Party Crystal Report Viewer ?

    The viewer provided with 8.5 developer edition of CR was embedded in a VB application. It does not provide option to select printers on client machine. Is there any third party viewer application or ActiveX or Java Component available to view and print the generated Crystal Report Files on a...
  9. it1234

    How can I make a page header for a subreport?

    You may try to insert a group in the subreport, which has only one value. (Select a column from the table which has only one value.). Place the label to be repeated in each page in the subreport, in the group header, and make the group header to be printed on each page through 'Change Group'...
  10. it1234

    Password for Report Instances

    No, not through the web interface. When creating the report instance directly in the desktop, the password field is blank. How to make it to be populated by default, like other fields in the Server Logon Tab?
  11. it1234

    Password for Report Instances

    Is there any way to hardcode the password before creating the report instance in the desktop? Right now the server name, database and logon user name are appearing in the new instance, and I need to type in the password once and save it for each instance. Thanks in advance.
  12. it1234

    Reports from CInfo Database

    Is there any ready-made tool available to report off of CInfo database?

Part and Inventory Search

Back
Top