Hi Guys,
There is an issue with voice call from IP to TDM in HIPath 3550 V9 system. IP to IP is working fine. But from IP phone to Digital Phone or from IP Phone to PRI, I am unable to hear the voice. I can view the B-channels being seized. I had put the latest firmware in HG1500. But still the...
Hi,
Am getting an error in Siemens HiPath Procenter, Config Sync Server is not running. I restarted both HiPath 4K and Procenter, but still the application is not active.
Could anyone help me to resolve the issue