Hi all, sorry for the long delay.
I checked "susip:rou=x,tru=all;" and MD110 used two trunks.
Then I installed EcotelTool and made the following configuration of routing table:
(oI21d08[789]*#) n G1:d
(oG1) n I2:1020
(oI22d08[789]*#) n G2:d
(oG2) n I2:1010
Now everything is OK. Thanks for...
Thanks for your help.
I misunderstood the counting of bits in parameters - is it starting from zero or one and from left to right or from right to left...
I was lost in way to find how to change varc... But finally found it:
Delete trunks:
ROEQE:rou=7,tru=1-2;
ROEQE:rou=7,tru=1-1;
Change VARC...
Well, I did
ROCAC:ROU=7,SEL=7110000000001010, SIG=511110000030, TRAF=00151515, TRM=5, SERV=2101000000,BCAP=001100;
but nothing changes. Do I correctly change D3 in SEL from 7110000000000010 to 7110000000001010?
Here is ROCAP:
<roCAP:ROU=7;
ROUTE CATEGORY DATA
ROU SEL TRM SERV NODG DIST DISL TRAF SIG BCAP
7 7110000000000010 5 2101000000 0 30 128 00151515 511110000030 001100
END
Is it correct way to configure it?
ROCAE:ROU=7;
ROCAI:ROU=7,SEL=7110000000001010...
Hello all,
I've a FCT Ecotel ISDN2-120 connected to MD110.
It works, but FCT use the second SIM card only when the first one is in use. In fact the first SIM card has a big bills, and second one - almost nothing. Is there a way to make a load balancing between two SIM cards?
here is part of...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.