I am linking 4 C object files together to produce the executable file. If the binary file does not exist, it creates the executable with my user owner:group. I can then re-run the linker and it will over-write the executable and the owner:group will remain the same. All is good.
If another...
I have a Pwr6 520 express server, with 6 drives: 2 146GB and 4 450GB drives.
I have installed a single VIOS on the 2 146GB drives and created 4 storage pools(VG's) in VIOS and assigned 1ea 450GB drive to ea storage pool.
I have done this in order to assign 4 virtual disks to my VIOC's...
With my customers starting to ask if my applications are certified to run on AIX7, I ve started to think about a scenario.
I have a Power6 520 express server, with a VIO partition and an AIX6.1 partition. I want to bring up another partition with AIX7
I know IBM offers the binary...
Ooopps sorry about that.
I should have been more specific as to the server machine type. The server I am using is a Power6 520 Express, 8203-E4A with processor feature 5634.
Model 8203-E4A 2-core 4.2GHz (rPerf = 15.95) (CPW 8300)
I am building a P520 Express server. I want to split the backplane so I can connect 3 of the disk drives to the internal SAS controller and the other 3 to an added SAS card. I have 2 cards available IBM feature 5901 which is a PCIe 4X sas card and an IBM 5912 which is a PCIX 4X sas card.
My...
You are so correct, I have had 2 new KVM's in the frame and have rebooted 1 of the servers, the video will come up, but I keep filling the syslog and errpt with KBDD and LFTD errors.
Almost like the newer kvms don't output a constant signal voltage.
The old Apex Outlook that failed is...
I have 2 PH660's that both have video cards in them, they are each cabled to a KVM. The KVM died and since then have rebooted the servers, now that I have replaced the KVM I still don't have any video. I assume when the server starts up it checks to see if there is return signal on the video...
I have many AIX servers ranging from 4.3.3.3 to 6.1. I always hate looking at the disks on the older boxes because I have to translate the 512 blocks or 1024 blocks to gigs. Where as the new servers have the df -g. Is there a way to upgrade the df command on the older servers to display...
I am currently in all the VIO docs learning as fast as I can. I have a P520 express server that has 6 disk slots in it. I am going to split the backplane and install 2 146GB and 4 450GB drives.
I'm trying to figure out how the disks will get assigned if I want to install 1 VIO server and...
The .netrc file worked great after auto login I defined an init macro and entered all my commands, added an extra line and saved.
Then in my script I just ftp hostname and everything moves.
Now I can have cron or another script run the first one.
Thanks for the direction.
I have an AIX box and a windows PC and need to have a script execute on the unix box that logs into a windows FTP server and does a put.
I can't seem to pass the username and password over and direction is greatful.
That is a great idea, I will setup the service processor just so its there, but we do have the network controlled and monitored power. Never thought about that I could just unplug it remotely and plug it back in.
This is not a usual occurence, but when it does happen it seems no one is around...
I've used the HMC before, its just like what I use on my Sun and HP boxes That is what I am looking for. I think the 660 are 11 12 years old. 6 way machines that get abused and dont show any sign of quiting. I knew they wouldn't have that kind of functionality, but I though maybe an add in...
I admin 5 AIX systems:
System Model: IBM,7026-6H1
Processor Type: PowerPC_RS64-IV
Number Of Processors: 6
A sunfire V215 Solaris 9 and 10
3 HPUX servers
The HP and Sun server are newer but they have a seperate port that configs to the Lan that gets pwrd up when you apply AC power. The...
The system stopped reponding to network pings at 5am and then the reset button was pushed at 0805 by another person. But when I look at this log it tells me the reset button was pushed at 0448.
So if the reset button was pushed at 0448, but it doesn't get writen to the log until the next...
Here is a snip of the errpt. Why does the SYS_RESET showup in the middle of these other entries with a different time?
Is there a different clock used to create the timestamp when the reset button is pushed?
813FE820 1019081007 U S MQSeries SOFTWARE PROGRAM ERROR
0BA49C99 1019080507...
We had a box go offline this morning and this is all I see in the errrpt. I'm researching with IBM now, but always like to hear other real world scenarios and discussions.
LABEL: SYS_RESET
IDENTIFIER: 1104AA28
Date/Time: Fri Oct 19 04:48:49
Sequence Number: 72968
Machine...
After I enter the root password I enter the fsck command and here is the output:
Type control-d to proceed with normal startup,
(or give root password for system maintenance):
single-user privilege assigned to /dev/console.
Entering System Maintenance Mode
Oct 12 15:40:27 su: 'su root'...
We have a development test box that has a corupted / filesystem. I've tried to boot to the cd, but it auto starts the installation. Is there a way I can boot to the cd to manually run the fsck. Here is the output when booting.
SunOS Release 5.9 Version Generic_118558-34 64-bit
Copyright...