  1. westpacsailor

    Definity G3 V6 station rings once daily at 01:01

    OK, found it: Trunk group 20 / Port 01V1901 on a TN760 circuit pack is the destination for 211 local emergency calls. Station 7101 is wired through an emergency transfer switch which is connected to Port 01B1901. TG 20 had Maintenance Tests set to Y. A cordless phone had been plugged in to a Y...
  2. westpacsailor

    Definity G3 V6 station rings once daily at 01:01

    Test was previously set to n (disabled) on 7101 and on all other extensions in the coverage answer group of which it is a member, so I don't think that is the issue. Display sys main indicates that testing starts at 0100 and ends at 0600, so it would appear that the beginning of the testing...
  3. westpacsailor

    Definity G3 V6 station rings once daily at 01:01

    I administer a Definity G3V6 on an MSC ship. Beginning several weeks ago, a single 8102 analog station rings once, at 01:01 every day. This station is 7101, which is the first station in the dial plan on port 01A0101. I have enabled intra-switch CDR, and have attempted to answer the single...