That was my original opinion at the start of this, they changed equipment they should fix the problem! However, after checking the messages both through internal means using the ISMC command and using external equipment between the two switches. There is no difference between the failed msg’s...
Thanks for the input, currently this route is only configured for outgoing long distance calls. When dialing the same number (tried multiple numbers to multiple area codes) over and over there is a large failure rate. Here is a scenario of what the monitoring equipment is catching on a failed...
LD carrier has cut from a FUJI to a VERAZ IP switch. 2400 works fine on the FUJI but fails 4 out of 10 calls on the VERAZ. Programming is a standard PRI w/ NI2 configuration. Layer 3 msg’s. reveal's a STATUS msg. "MESSAGE NOT COMPATABLE WITH CALL STATE" . This site has over 20 PRI's all NI2 and...