    IPNat.sys and Windows 2003 Firewall

    hi, I have just inherited a system that I'm to support – Win2003SBS, SP2. One of the problems I have encountered is that the Windows Firewall/Internet Connection Sharing (ICS) fails to start. I searched this issue and most of the solutions points to disabling NAT in the RRAS. I was about to do...
  2. kontech

    wiring alarm monitoring system with RJ31

    I was just going pretend that I'm not concerned with all liability aspects as it was the first time I did this kind of wiring... I'm not so clear who the liable party would be in a case of potential failure in a fire situation as the system was fully tested and certified by the alarm company...
  3. kontech

    wiring alarm monitoring system with RJ31

    I have already wired RJ31s and I believe the alarm system test/inspection passed OK. www.kontech.net
  4. kontech

    wiring alarm monitoring system with RJ31

    Picked up two RJ31x by Allentel yesterday and wired the two phone lines for the alarm. Thanks again for guidance in this project. www.kontech.net
  5. kontech

    wiring alarm monitoring system with RJ31

    Thanks, for clarifying. Need to get RJ31's now. www.kontech.net
  6. kontech

    wiring alarm monitoring system with RJ31

    This is helpful, though it made more confused. Right now, I have a two POTS coming from Dmarc, each terminated on RJ45 on pair 1 & 8. I just was told by the contractor (how doesn't know much about it) that I need to terminate one of the telephone lines using pair 4 & 5 and the other on 1 & 8...
  7. kontech

    wiring alarm monitoring system with RJ31

    I do have a dial tone on both Cat5 jacks and the two middle pairs are used. I tested with with the butset. I guess that's all I need then. Thanks. www.kontech.net
  8. kontech

    wiring alarm monitoring system with RJ31

    Hi All, I'm working on a commercial wiring project and I was approached to wire alarm monitoring system with two telephone lines (POTS) though RJ31 jack. There are two ribbon cables coming out of the alarm box each with RJ45 end, already wired inside. The way I wired is was I used RJ45 jack and...