I dont have access to UDP tables :/ I wish I did... it would have made the Asterisk to Definity integration alot more manageable.
However, routing calls via coverage path and coverage path remote is working well for us too.
The biggest pain is the decision by "greater powers" to discontinue...
I have the following subscribed ports availability:
TOTAL SUBSCRIBED PORTS
ISDN BRI Ports: 0 1000 1000
Station and Trunk Ports: 1394 6 1400
I am using X ports for extensions routed through a DS1 interface tied to Asterisk VoIP PBX. Our...
Thanks so much for everyones help. My job requires... like a lot of you... an office with many "hats", and this is one that I am relatively new at. I think I could pass a google certification in a heartbeat. I really appreciate all of you who dedicate some of your time for people who need you...
I found this on ebay. It is a 48V .4A power supply from lucent....
Will this work:
http://cgi.ebay.com/Lucent-1151A1-Power-unit-class-2-phone-power-supply_W0QQitemZ330277362907QQcmdZViewItem?_trksid=p3286.m20.l1116
OK... I can do that.
Just to make sure then... how many pairs are needed for the console itself?
If it is using Phantom power now, and I put 48VDC on the brown pair, will it cause an over-voltage condition?
I guess what would answer my question here is a pinout for the connection to the...
OK... here is what I see in the MDF. The person that handles the wiring of each extension from the MDF has no documentation as to where the console is punched down. The port for the console in the switch is 01A0301, and I found a cable on the wall attached to a 66 block that says Aux 01. On...
I am revisiting the relocation of the attendant console here in thread690-1464273.
What I need to know now is how to tell if I am Phantom Powered or Locally Powered.
How do I tell if I am powered from the auxilary slot or not?
I have been directed to explore my options in relocating our "Main Switchboard" from the IT Dept. to the Campus Safety office accross campus. My questions are simple. Since the Attendant Console operates on a digital line, is there distance concerns if the move is indeed warranted? If there...
Im not sure if what I am doing is the norm, but I do have something suitable working for our environment. I would be happy to explain to anyone what I have done on the phone. I will post later all of my configurations via a white paper, but6 it is not complete, and i dont want to post in...
I have a working configuration with Asterisk and our Avaya Definity G3si, but have a particular issue that is driving me crazy. On the definity, we have extensions setup that cover 2000-3299. These are directly associated with DIDs that work with no problem. On Asterisk, we have extensions...
PHQNEMAN,
I would definately like to take advantage of this if I can configure it properly. I have created extension 4002 as an x ported station; I have changed cos 12, giving it console permissions, but I did not see any place to assign that station in the COS. I may really be exposing my...
Thanks for the suggestion, but I do not have vectoring enabled on the Definity. I have decided to setup each station on the Definity as an x ported station and create its own coverage path. I then change the coverage path and set point1 to a coverage remote number. I then do a change cov r...
PHQONEMAN,
I have tried to figure out what you suggested, and the only way I was able to get anything to halfway work was this:
1) Create a new coverage path and stroke all criteria to 'y'; then set Path 1 to r1
2)I then go to change coverage remote and in r1 I put the TAC of the correct...
We have an Avaya Definity G3si Ver.6 that handles all of our campus inbound and outbound DID's. We have had no Maintenance agreement with Avaya since the mid 90's, and when the Definity was upgraded to Ver.6, Uniform Dialing Plan was not purchased as one of the options. I have successfully...
I have run into another road block.... Uniform Dialing Plan is not enabled in system-parameters custermer-options. We are on version 6 and no one from avaya will touch it. It is included in Versions 9 and up, but would have had to been purchased as an option when Version 6 was. So... here is...
I have the D-Channel up and working now. It seems that with all of the configurations I have encountered online, the one step missing is adding the data module, processor configuration, and the link configuration.
I had problems adding them after everything else, so I started from scratch add...
I have figured out why I had problems adding the data module. The Definity G3s1 V6 PBX we have had only one processor interface installed. 1 port was used for audix and the other ports were used for ISDN trunk lines to AT&T. We bought a new TN765 V17 processor interface board and installed it...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.