It would take an act of congress to get someone here. Is there any other suggestions at this time? It has to be something small. I want to ou loop 13 that I see in load 60 and there's a TMDI card in the CS1000E located at 0 1 3 how do I out that card and reinstall it. Please help Thanks...
Here are the steps I performed
1. LD 60 disl 13
2. Ld 16 outted the RDB
3. LD 14 outted the trks
4. LD 17 finally got the DCH 23 outted
5. Ld 17 chg cequ at the DLOP prompt i used X13 which worked.
Now when I prt cequ LD 22 pri 13 isn't there good.
When go to LD 60 stat 13 the loop is there...
LOL I have had a hard lesson the the last several weeks. Guys thanks so far for your help. If I could call the vendor in I would, but at this time I can't. I so amazed of what I have learned so for, but I missing a step. Please help. When I go to LD 60 Stat 13 how do I out that loop I done...
Im' getting somewhere. Here are the steps I performed
1. LD 60 disl 13
2. Ld 16 outted the RDB
3. LD 14 outted the trks
4. LD 17 finally got the DCH 23 outted
5. Ld 17 chg cequ at the DLOP prompt i used X13 which worked.
Now when I prt cequ pri 13 isn't there good.
When go to LD 60 stat 13...
Hey guys I was sent the link below that was very helpful I found the definition of phantom TN's, and will continue to search for the definition of virtual TN's or trunks I'm assuming it means the samething. Configured in software, but no configured hardware...
Guys I'm getting some where I configured trks in ld 14 using new 23 then the system configured all 23 for me.
I can go to LD 60 and do a stat 13 and all channels are idle / DID / VCE with the ch 24 being DCH 23.
The TMDI card is physically located at 0 1 3 and when I built the d channel on...
How can I out adan dch 23 and rebuild it or change the MG_CARD prompt from 0 0 1 to 0 1 3 where the TMDI card is physically located?
I have dch 23 and the system will not allow me to out it in LD 17. Here's some of the print put from LD 22
Adan dch 23
Ctyp tmdi
Mg_card 0 0 1 should this be...
Here's some of the things I've done please help am close
1. I have TTY 13 and the system will not allow me to out it in LD 17 this is what I get.
Ld 22
Prt cfn
Adan tty 13
Ctyp ****
GRP
Dnum 0
Des test 013
Flow no
User sch
Xsm no
Tty log 0
Banr yes
When I try to out this I in LD 17...
Hey I may Have to look into a vendor, but I getting some where. I wen to ld 60 did a stat saw loop 7 ch 1 - 23 was uneq with the ch 24 being the D ch. I tried to enable the TMDI card in the CS1000E and it's telling to go enable the MSDL Card where do I go to do this?
Everyone I've worked on meridians, but every job I go to everything is configured so I do the MACS. I've been tasked to configure trunks mainly PRI and DISA for the CS 1000. Can some one give me a elementary break down on how to do this. I know you use multiple loads, but can yall help me...