You could try parallel ringing facility.
PLLNI:MDIR=3200,SDIR=3199;
You can have up to 2 SDIR number for 1 MDIR.
Or you could do and immediate diversion for 3200.
CDINI:DIR=3200,DIV=3199;
You can use Trilliums (Telephone Recording Adapter) to tap off the audio from the hand set. There are passive and powered Trilliums available for the distance issue.
Can someone help me, what voltage or indication I can expect on the Watchdog output when the system is healthy and what O/P pair it should present it self. I am using ALU2 and BC10.
We are using QDLU. Ericsson is supporting it anymore and we have noway of sourcing this cards. That is why we are looking for an alternate option, which is called EDLU. Apparently they are using this in Singapore and Ireland. It is more like an HDU, pluggin card but has an interface for the old...
to whosrdaddy,
I wouldn't recommend to connect modem on port1. We used to use westermo modems on port one, it locks up NIU port now and then. It works fine on port2 and port3. Interesting .....
Hi guys,
Anyone know where I can source some Backlit flouresent lambs for Ericsson CTT-10 dealer keyboards? The one we currently use is manufactured by Sharp LQOB101. I can't find any suppliers.
I think you can do this by setting up the Language to Exchange Language "F". give it a try. you need to re initiate the extension.
KSEXI:DIR=3000,EQU=X-XX-XX-XX,CAT=XX,CALALT=1,ITYPE=20,LANG=F;
KSTSC:LANG=0,STRNO=12,STRING=”EXT 3000”;
/**/
Let me know if it works..