Thanks for your answer,
Unfortunately the problem was in something quite different.
I had to disable the usage of CDI interface in NetWorker by creating a 0 Byte file
touch /nsr/debug/cdidisable
Restarted the NetWorker daemons, checked for all tape device to show up option "CDI: not used"...
Hi,
I have a case with Storagetek L700e that has 6 SDLT tape drives connected over 3 SCSI to fiber routers (SN3250)to a switch.
The Legato lus_add_fp_devs script adds only 3 lus instances as it only sees the 3 routers and not 6 drives. So the inquire command sees only 3 tape devices.
The...
Hi,
I contacted StorageTek, and after going through all the mcode upgrades (not that any of them was helpful) the problem was fixed by replacing the hand assembly, since there was no way to calibrate the "slide the tape in" movement.
Hi,
I have a problem with two L700e libraries. They both have a combination of LTO and SDLT drives. The problem is with the SDLT drives. The hand does not put the SDLT tape far enough for the drive to accept it. The hand pushes it three times in but not far enough; the tape keeps coming out...