Im Using a terminal program called ZOC to interface to PABX systems.
It uses REXX for its macro's with some extra code to send data/commands to the terminal etc.
Basically all i need is a code so that a variable that's been specified in zoc with a value i want to be able to poke that value into...
Hi All,
Im going through the process of using ZOC to do my programming on the CS1k instead of procomm plus (due to my new PC is windows 7 and cant get UWIN working on it for SSH and RLOGIN sessions).
So far so good. Very similar to aspect on the scripting side. However on Aspect i used to be...
Hi All,
Im going through the process of using ZOC to do my programming on the CS1k instead of procomm plus (due to my new PC is windows 7 and cant get UWIN working on it for SSH and RLOGIN sessions).
So far so good. Very similar to aspect on the scripting side. However on Aspect i used to be...
Thanks Hatched, but that wont work as the agents answer the calls for both companies.
I didnt think it was possible. I guess they'll just have to put up with it that on hold they get the right MOH but if they transfer it will have to be the other MOH!
Hi All,
I have a customer who has a CDN, Application and skillset to answer calls from another companies reception number.
Now the call works fine and goes through to the agents OK. However when they transfer the call to another extension the callers get the Music on hold thats specified in the...
Firebirdscrambler,
I think you misunderstood what i was trying to ask.
BCMAmp is working fine and so is the MOH on these systems. Half the time the customers forget to turn on the CD player etc thats attached to it.
What i was asking was to set up a 3rd party server somewhere on their network...
Hi all,
I was wondering if any of you have set up the BCM to receive streaming from a central server.
I have a customer with approx 80 BCM's on their network and the problem is that half the site the MOH doesnt work because their Audio MOH source is faulty or not turned on etc. I have suggested...
Hi all,
just wonmdering if you can tell me where i can get a copy of the pC pro for the 96i?
I do have it somehwhere but no idea what ive done with it and have to do a bit of programming on one of these baby's
John
So what you are saying is that
Incoming call comes into an extension on the Nortel from telephone 12345678.
That extension transfers the call to and extension on the CISCO via the QSIG tieline.
The Cisco Extension gets a caller ID of 12345678.
If thats the case can you post the DCH...
Its actually a problem with the macro.
I had to modify the MV macro so it will work on office 2007. While i was there i put in some extra goodies like 1140/1150 etc...
PM Me with your email and i'll send it to you :)
Also what lights are on your PRI card?
Is your CC light on?
You might just have to unjack the PRI and reinsert to get the clock controller going
In Load 60 When you dis cc 0 0 and re enable it if the clock controller card is working you hear it click and the CC light start flashing.
can you send a printout of your LD 73
PRT
PRI2
LPTI
Could also be something to do with that..
Also what cabs you running?
I know that the 11c Cabs did have some issues with clocking with MGC cards when Release 5 first came out..
2 problems i can see...
Firstly seems like you have fast clock switching on, which is a no-no on a release 5 up system. To change this
LD 73
CHG
PRI2
SYTI
under the EFCS set it to NO.
This should alsi resync your clocking and hopefully fix the issue..
If it doesnt then you might need to bounce...