Hi,
Does Nortel Secure Network Access Switch 4050 supports Radius Accounting and Radius Accounting Extended? Does it send Acct-Input-Octets and Acct-Output-Octets packages? Thanks
Hello I'm running a dhcp server with two IP addresses (different subnets) in one NIC. It connects to a 350 switch. There are two VLANs for that switch, say VLAN 1 and 2. Here is the VLAN table that I assigned:
VLAN 1: Port 1-5
VLAN 2: Port 5-10
So I plugged the DHCP server to port 5 and then...
Hello:
When I started the 3Com OfficeConnect Managed switch 9 the Alert LED remains on and the unit becomes unresponsive. The switch passes all "Power-On Self tests (POST)". However, after the last test it says: <ERR> Runtime Loading Fail - System Halt.
Is there anyway I can fix this switch...
Hi all,
My workplace has multiple subnets with their own gateways and dhcp servers. Is it possible for me to use 802.1Q + multinetting to route my vpn clients to their subnet respectively? Or there is another way to do it?
Any help would be appreciated
Hi lefaboune
Many thanks! It works perfectly!!
I tried to download the ascii configuration file from the switch and I wasn't able to read the password (it was encrypted).
Then I copy and paste that CORE section, change the password, and upload it back to the switch and everything works...
Hello,
My company is using a Nortel 470-48T switch and we lost the password for this switch. I know there is a recovery method but we can't restart the switch and we don't want to lost all the vlans.
Is it possible for me to use some brute force software to crack the password? any help would...
thanks anthonyanderberg,
i see. today i tried to use snmpwalk and sometimes it work. here is the problem: there are two subnets in my network, say: 3 and 4. the switch is on subnet 3. sometimes i can use snmpwalk to pull out the snmp data by using the machines on subnet 3 (not the full mib...
Hi i have a Nortel 470-48T switch and everything works fine until yesterday...
I can't access the switch via SNMP and HTTP, but the traffics are ok (it is still pingable). I don't know if it is software or hardware issue. Any help would be appreciated.
Thanks,
jason
Hello guys. I'm a new Optivity user. I have a question regarding to the ipAddrTable for my Nortel and 3COM switches.
There are 10+ devices plugged to the switch. However, according to the ipAddrtable, it stores only one ip address (the ip for the switch). Do I need to manually enter my...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.