Hello All,
We are having issues connecting my Avaya G3r to a Nortel SL100 switch. This is what we have so far:
1. We recieve Nortel calling party name and number with a leading character that resembles an I with two dots directly above it. What is this character and how can we remove it?
2...
Greetings,
Can someone please explain what the ISDN Layer 2 Status Test #647 relates to and how do I correct it? My signaling group shows out-of-service. I am attempting to connect an Avaya G3r version 11 to a Nortel PBX; distant end tech says D channel bounces up and down. Is there a way to...
I have an Avaya G3si that was previously installed and I have to reinstall it from the ground up. Does anyone know where or how I can find complete G3si instructions?
Hello,
I have an Avaya PPN and several EPNS connected using ATM technology. I recently upgraded the firmware on all TN2305 circuit packs and customers on one EPN continue to complain of sporatic garbled sounds (one-way). Is anyone else having this problem? Any ideas on how to resolve?
Greetings,
Can anyone tell me how to or where to find instructions on setting up an Avaya Dual Port Network on a G3R switch? I have looked high and low, with no luck.
Can you advise/tell me what I have to do to convert from 5-digit dialing to 7-digit dialing on an Avaya Switch? I have version 11. I am not sure what screens have to be addressed or where to find the documented instructions.
Lee
Greetings...
I need help connecting a Spectel Conf bridge and a G3R v11 switch. I think connectivity is in place and just need help with programming the trunk group? hunt group? I am having a problem with the Spectel answering the G3r. I am anxious to hear from someone with a funtional...