Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. masoud12

    hi what reasons the following alar

    ENTER PASSWORD < AUTHORITY CLASS 5 (C) COPYRIGHT ERICSSON ZANJAN 20OCT12 10:29:00 1-0-23-02 <SCICP; MASTER LIM/GSM CONFIGURATION DATA MASTER 2ND MASTER 3RD LIM GSM LIM GSM LIM 0 2 3...
  2. masoud12

    hi what reasons the following alar

    hi Satellite1900 ILLSP; COMMAND UNKNOWN <GJLSP:PRINT=ALL; GROUP JUNCTOR LINE STATUS EQU = 1-0-00-0 GS-MULT 0-0 MCCL GS SIDE 0 ACTIVE NOT ACTIVATED NOT SIGNALLING CLOCK CONTROL SIDE 0 ALARM 0010 0000 1100 0001 EQU = 1-1-00-0 GS-MULT 0-1...
  3. masoud12

    hi what reasons the following alar

    hi what reasons the following alarms in md110? CLASS: 4 22 FAULTY GROUP SWITCH MODULE DATE TIME ALP NOIF GSSIDE GSM 28JUL12 11:19:08 4 1 0 0 CLASS: 3 55 PARITY ERROR IN GROUP SWITCH DATE TIME ALP NOIF GSSIDE GSM 28JUL12 11:17:39 2 1 0 0...
  4. masoud12

    FAULTY PCM-LINK (GJU)

    VERSION: LZY20306/9/CNI29/R1A DATE: 29JAN12 TIME: 13:41:03 CLASS: 4 22 FAULTY GROUP SWITCH MODULE DATE TIME ALP NOIF GSSIDE GSM 25JAN12 14:16:00 7 1 0 0 CLASS: 3 24 FAULTY PCM-LINK (GJU) DATE TIME ALP NOIF GSSIDE GSM 25JAN12 14:13:57 2 1...
  5. masoud12

    add a program unit from a hdu

    I want the program unit EDH to its INL in original hdu. LAPUL:LIM=1,UNIT=EDH,PATH=SYSN/USR1/SES/DR/INL/P; :It performs :The program unit EDH will move from HDU to LIM1.
  6. masoud12

    add a program unit from a hdu

    All steps should I do: Uninstall the original HDU: BLEQI:EQU=X-X-X-0; FIMOE:SUBFS=SYSSUBFS11; FIMOE:SUBFS=SYSSUBFS21; IOSIE:NODE=SYSN,IODEV=SYSDISK1; Switch off the original HDU. Install the new HDU: Switch it on. IOSII:NODE=SYSN,IODEV=SYSDISK1,SIPOS=3,SUBFS=SYSSUBFS11&SYSSUBFS21...
  7. masoud12

    add a program unit from a hdu

    Code sequence: LAPUL:LIM=1,UNIT=EDH; SFCEI; SFPUI:UNIT=EDH,LIM=1;
  8. masoud12

    add a program unit from a hdu

    sorry correct this section: Install the new HDU: Switch it on. IOSII:NODE=SYSN,IODEV=SYSDISK1,SIPOS=3,SUBFS=SYSSUBFS11&SYSSUBFS21; FIMOI:SUBFS=SYSSUBFS11; FIMOI:SUBFS=SYSSUBFS21; BLEQE:EQU=X-X-X-0; now What should i do?
  9. masoud12

    add a program unit from a hdu

    hi fcpli now system worked with HDU original that dos not EDH program unit. i want replace HDU original with HDU that have Program unit EDH. so for this do step as follow: Uninstall the original HDU: BLEQI:EQU=X-X-X-0; FIMOE:SUBFS=SYSSUBFS11; FIMOE:SUBFS=SYSSUBFS21...
  10. masoud12

    VERSION: LZY2030651/8/R1A DATE:

    hi wialdo thanks for reply i end sysn and initiate it again and DUSYI:DUMP=all worked . as follows: BLEQI:EQU=001-0-23-0; FIMOE:SUBFS=SYSSUBFS11; FIMOE:SUBFS=SYSSUBFS21; IOSIE:NODE=SYSN,IODEV=SYSDISK1; IOSII:NODE=SYSN,IODEV=SYSDISK1,SIPOS=3,SUBFS=SYSSUBFS11&SYSSUBFS21...
  11. masoud12

    VERSION: LZY2030651/8/R1A DATE:

    VERSION: LZY2030651/8/R1A DATE: 03AUG12 TIME: 12:58:54 CLASS: 4 56 THE SYSTEM DOES NOT HAVE AN ACCESSABLE BACKUP DATE TIME ALP NOIF EQU BRDID 03AUG12 12:58:30 2 3 001-0-23-00 69 CLASS: 3 106 FAULTY IPU BOARD OR CONNECTED I/O DEVICE DATE TIME...
  12. masoud12

    add a program unit from a hdu

    i have a hdu(1) that does not EDH program unit, and have a hdu(2) that consist EDH program unit and is reserve. so i replace hdu(2) with hdu(1) . how can EDH remind in hdu(1)?
  13. masoud12

    FAULTY IPU BOARD OR CONNECTED I/O DEVICE

    salam sia30 inam mobile mane 9193412720 inam mailam msd.cmp2001@gmail.com moshtage sohbat
  14. masoud12

    FAULTY IPU BOARD OR CONNECTED I/O DEVICE

    thanks for replies CATII:DATE=2010-07-28; my problem solved.
  15. masoud12

    FAULTY IPU BOARD OR CONNECTED I/O DEVICE

    <IODDP; I/O DEVICE DATA NODE IODEV/SUBFS EQU/BPOS SIPOS VEND/USAGE STATUS SYSN - 001-0-23 - - IN SERVICE SYSN SYSDISK1 001-0-23-0 3 TEAC IN SERVICE SYSSUBFS11...
  16. masoud12

    FAULTY IPU BOARD OR CONNECTED I/O DEVICE

    <allop; ALARM LOG IDENTITY: MIANEH VERSION: LZY2030651/8/R1A DATE: ******* TIME: 05:20:23 CLASS: 3 106 FAULTY IPU BOARD OR CONNECTED I/O DEVICE DATE TIME ALP NOIF EQU BRDID INF1 ******* 04:43:30 1 1 001-0-23-00 69 5 END < how to solved...

Part and Inventory Search

Back