  1. bradfordcitybantam

    Telneting into an iSDX

    Don't forget, if you mess up the config of the environment it can stop the system loading up!
  2. bradfordcitybantam

    Interfacing Realitis DX with Seltek Voice Manager PC.

    Speed of CIL data depends on software version. IIRC it's 1200 on older software & 9600 on newer, no parity or stop bits. CIL data can also be output on the ethernet port, parameters in the ASMI interface determine the destination the data is sent to. Unfortunately it's unicast rather than...
  3. bradfordcitybantam

    "number is a display number" when MEXing etc

    Worked a treat! Many thanks..
  4. bradfordcitybantam

    "number is a display number" when MEXing etc

    Hi, Came across a new one today, or new to me any. When trying to mex two numbers I get an error message saying "number is a display number". Software is version 9.2 Anybody any ideas? TIA ?lex 2989 DN2989 BC0116 A04 D TP01 CS01 TA15 MOH 000 ?lex 5899 SN5899 SPARE CS00...
  5. bradfordcitybantam

    Interfacing Realitis DX with Seltek Voice Manager PC.

    You can check valid CIL data is coming out by hooking up a terminal emulator to CIL port. Also RCIL command will resume CIL if it's been disabled in the past.
  6. bradfordcitybantam

    OUTPUT EXTS WITH COS TAC

    Try lex a e Doesn't come out as csv, but a decent spreadsheet will be able to parse the output. However some tweaking will probably needed, especially if you've given names to extensions