  1. Canmi

    The name does not appear during an internal call between extensions in a clustered environment

    The systems have the same COS index for Ip Trunk, and this COS it´s sharing across the systems? Is possible that system A and system B don´t have the same COS and you don´t checked both of them? Options to check: - Calling Party Name Substitution - Name Suppression on Outgoing Trunk Call -...
  2. Canmi

    Using PuTTY to bulk change set's programming

    If you have a system to work in your lab, test script with Procom, capture when you launh script, and save how txt. You will be able to paste it you can paste it through putty. I´m not sure if you can stick a very long block or if you limited to send or if you will have to paste in batches
  3. Canmi

    MGC TTY´s don´t works

    Thanks all Yes, I tried to create tty in other MCG, and they are blocked. When they are blocked, I can´t enable - disable, because I don´t have acces to the system. All tty´s are blocked. I don´t tried whit a virtual tty through putty. This is an option... I have now some patches, but I...
  4. Canmi

    MGC TTY´s don´t works

    Thanks to all... Yes, all tty was configured like this: ADAN TTY 0 CTYP MGC IPMG 4 0 DNUM 0 PORT 0 DES Mant BPS 9600 BITL 8 STOP 1 PARY NONE FLOW NO USER MTC TRF SCH CTY BGD CUST 00 XSM NO TTYLOG 0 BANR YES And cable is not the problem, because tty´s...
  5. Canmi

    MGC TTY´s don´t works

    CS1000 rel 5.5 3 TTY mcg port - one for maintenance - second for PMS . third for tarification In a time, 3 ports don´t work and I need to restart the system... Besides, after reboot I need re-write pms port because I have PMS611 error. Any idea? Thanks to all
  6. Canmi

    3300 ICP ESM

    Any option that we give is susceptible of not working well, depending on the menu or sub-menu that you use. For me, best option is: F12/Emulation/Document mode and user agent string (i´m not sure real name for this option in english version) wiht IE7 selected, but is possible that some menus...
  7. Canmi

    SIP-DECT 622d with RFP 35

    I started a dect system with 50 rfp35 ip a few days ago. Testing, we broken the AP with the license file. This caused the orange flicker that you indicate, but all sytem worked fine, without this ap.... When you make a search with the OMConfigurator, down, in the log, can you see confirmation...
  8. Canmi

    Multiple 5550 Consoles

    Only one question for your knowledge: - One call arrive to console 1 - This call is transfered to other extension - The call is not answered and return to consoles - The console don´t return to the same console. Ring in all active consoles
  9. Canmi

    TFTP files for external Server

    Why customer likes this? Do you have only Minet phones?
  10. Canmi

    Room Move

    I read the background documentand but I haven´t see anything about this option. I will tell with the interface software vendor for view the option... Thanks every people
  11. Canmi

    Room Move

    When the switch is installed in a Hotel, you can configure one TTY port to work with an interface of some hotel managment software (Brilliant, Opera...). If someone do a check in or check out, or wake up call, or change of room status, the interface send the information to the PBX. The check in...
  12. Canmi

    Room Move

    Hi Someone know if is possible to move one room in a cs1000 when I used Hospitallity? Check In: se cp 124 "name" ch in Check out: se cp 124 ch ou Move: ? Thanks to all
  13. Canmi

    MONITOR

    OK. I´m Sorry. The command are perfect. The problem was that I program the switch for the TTY 7, and the monitorized was for the tty 0. Sorry all the peolple, and thanks for the lessons. Tnaks
  14. Canmi

    MONITOR

    Hi I has tested your manual, but I don´t see any traces. You know how reset all comands and restart? When I put stat mon in ld 96, I can see .stat mon TRACE OUTPUT DCH LOG : OFF DCH TTY : ON ACTIVE TRACES what am I doing wrong? Thanks
  15. Canmi

    MONITOR

    You left me crazy. I test all. After I tell you how it turned. Thank
  16. Canmi

    MONITOR

    Hi I´m lookink to monitoring dsl Bri´s in the switch, CS1000 rel 5.5...In old versions, the command setm omsg 12 0 3 7 it´s good. When I put this comand, the switch return point but the "set mon" command return .stat mon MSGO DIS FOR AML DIS FOR ELAN MSGI DIS FOR AML...
  17. Canmi

    IDLE SET DISPLAY

    I had charge PEP´s in the CPPM Signaling Server, and the problem persist...
  18. Canmi

    IDLE SET DISPLAY

    Hi. I connect and programmed a 2004p2 ip phone, and it displays the name. The problem is with 1200 serial. I don´t have any 1100 serial. The Signaling Server is CPPM. Any idea? Thanks...
  19. Canmi

    IDLE SET DISPLAY

    I have this problem in a 1110, 1120 and 1130. I have not found anything to indicate that this new series of phones do not support barndline I have only one call server (no redundancy). The SS are CPPM. If I change this prompt with Element Manager, not me make the change. Ah! Thanks to all...
  20. Canmi

    IDLE SET DISPLAY

    It´s OK: REQ chg TYPE parm LPIB HPIB 500B SL1B DTIB OB NCR MGCR NCPU CFWS CML ALRM ERRM DTRB ABCD K R FCDR PCDR TPO TSO CLID DUR5 MLDN MARP IPIE FRPT DCUS MSCL PMSI NDIS OCAC MTRO SBA_ADM_INS SBA_USER BCAP IDLE_SET_DISPLAY Tecmo_Test MODIFY yes SUPPORTED_TEXT_ONLY yes IDLE_DISP_STRING...