  1. Tankgirl

    V8.6 Provider cannot be found. It may not be properly installed.

    No some clients are running Pervasive 2000i, V8.1 or V8.6. The client getting the connection error is running 8.6
  2. Tankgirl

    V8.6 Provider cannot be found. It may not be properly installed.

    Thanks. When installing Pervasive WGE, they call the Pervasive Installation
  3. Tankgirl

    V8.6 Provider cannot be found. It may not be properly installed.

    I am not sure how Pervasive is installed, our app is an add on to an accounting system which installs all the required programmes. Have requested the info from them. How would I do the name resolution etc?
  4. Tankgirl

    V8.6 Provider cannot be found. It may not be properly installed.

    I can connect through PCC perfectly on both machines. The connection string is: Driver={Pervasive ODBC Client Interface};ServerName=SERVER;dbq=DATA I haven't tried the DEMODATA - will ask the client to test this and let you know. Mostly the app can connect using the...
  5. Tankgirl

    V8.6 Provider cannot be found. It may not be properly installed.

    Machine: XP Pervasive Workgroup V8.6 No domain controller / Workgroup is set up P2P Can't connect to a database on the server or locally on the machine. Tried the following connection strings without any luck: Provider=PervasiveOLEDB;Data Source=C:\Folder\Data...
  6. Tankgirl

    Size limitation to DOMDocument.xml

    I am new to xml so hopefully this is really easy. I am having a problem with the size of the data returned from the server. Although when I write it to a file on the server it has all the information in it, when I receive it on the client side my string is empty. If I return less data then...
  7. Tankgirl

    FSO.GetSpecialFolder not returning Windows Folder

    Really weird - managed to get it working - had to change to using "WScript.Shell"
  8. Tankgirl

    FSO.GetSpecialFolder not returning Windows Folder

    Hi, I am trying to get the Windows folder on a clients machine using the File System Object, i.e. FSO.GetSpecialFolder(WindowsFolder) Instead of returning "c:\Windows" it is returning "C:\Documents and Settings\g2server\WINDOWS" On all other machines I have tested it on it returns the...
  9. Tankgirl

    Btrieve conflict - database unavailable ??

    Thanks Mirtheil - I got the client to resend the data - seems when my pc crashed it must have corrupted the files. Tried opening the new file and it seems fine.
  10. Tankgirl

    Btrieve conflict - database unavailable ??

    Here it is but seems to be a bit garbled: DÅP€ 137007TM108B1040450 ð¿}Ô%­ I²Ô...
  11. Tankgirl

    Btrieve conflict - database unavailable ??

    Mirtheil, Everything is local - get an error when trying to open the file with the Function Executor. Btrieve status 30 "The file specified is not a MicroKernel file." Btrieve Version: Client 8.0 Local MicroKernel 8.10 Win32 Thanks
  12. Tankgirl

    Images set to black squares

    Everytime I open my VB Project 4 of my images on the toolbar are set to a black square, I have to then relink them into the Image List control - which becomes very frustrating cos you have to first delink the image control from the toolbar. Any suggestions?
  13. Tankgirl

    Btrieve conflict - database unavailable ??

    Hopefully you can shed some light... I had to format my pc and reinstall everything - I have the same versions of all software but for some reason I am getting Error 30 on files that were working fine? I am running Pervasive.SQL V8 SP1. Getting this error when trying to open the file through PCC.
  14. Tankgirl

    using the msde engine instead of sql server

    Hi, I am struggling to get the list of servers when MSDE is installed on the client and SQL on the server. Get Active X cannot create object but all the dll's are on the machine. What am I missing? Thanks
  15. Tankgirl

    Unable to connect to the relational engine

    Managed to connect to the database by creating a db connection in the PCC and then changing the connection string. But it only connects the first time - the second time it won't connect. Error connecting to Pervasive....
  16. Tankgirl

    Unable to connect to the relational engine

    I have set the gateway locator to my machine to test - do I need to do anything else i.e. change the connection string? It creates a ~PVSW~.LOC file in the data directory with OSDEV1 \\Osguru\osguruC\Pastel\CLOTHSRU\~PVSW~.LOC (data location) OSDEV1 being my machine Haven't done this before...
  17. Tankgirl

    Unable to connect to the relational engine

    Managed to get the data working locally - there was a pervasive loc file in the directory. Once I deleted this all was working fine locally. I then copied the working data onto the server and the same error occurs. Pervasive is not installed on the server just the data folder is stored there...
  18. Tankgirl

    Unable to connect to the relational engine

    I am connecting to an accounting system's data through this connection so there is no database name on the server. i.e. As long as the DDF files are present then I am usually able to connect? What is SPX?
  19. Tankgirl

    Unable to connect to the relational engine

    My app uses the following connection string Provider=PervasiveOLEDB;Data Source=Path; to connect to a Pervasive database, all works fine with Pervasive 2000 but on V8 it won't connect it raises the error "Unable to connect to the relational engine (is Database Name and Server...