    Remote network region with audix g.729

    Either CMM or IA770 both need to be G.711. Typically we put the VM in to its own network region to accomplish this. Typically use NR 99. That way calls between site "a" and site "b" (NR 1 and 2 for example) would use g.729. When NR 1 or 2 calls 99 (NR for VM) it would use G.711. That way only...
  2. MacSourceNOC

    Modular Messaging 5.2 Installation

    We are doing the same thing for one our customers as we speak.... As mentioned, the 5.2 installation / migration doc goes over all the steps. But in a nutshell, you use DCT to analyze the existing MAS, and backup the MSS. You image both the MSS and MAS, you restore the MSS from the backup, and...
  3. MacSourceNOC

    Strange MSS MT Linux alarms...

    Another one of our guys did the upgrade, he dose not remember seeing any warnings. But if there something i can do to double check that, i'm all for it! Thanks... --Mike
  4. MacSourceNOC

    Strange MSS MT Linux alarms...

    We recently upgraded a Modular Messaging (Avaya 3500 hardware 1 MAS w/ MSS) from 4.0 to 5.1 and are getting 2 alarms on the MSS that I can not find any info on. App Resource Location Alarm Alm Type Code Lvl MT LINUX GROU P 1 MIN MT LINUX...