  1. KarstenHuhn

    SX-200: Installation and Maintenance Course material

    Hi guys, I recently bought an SX-200 CXi from Ebay, just for fun. I already found some admin guides in the internet and I have access to official MITEL documents as well but this 200 stuff is simply too old. To complete my documents it would be great if anyone could share an Installation and...
  2. KarstenHuhn

    VXworks corrupted with incomplete IP address of sw0

    The problem is resolved. I just copied the default system.cfg to the flash card again and the fault disappeared. Thanks for your help, guys. Karsten
  3. KarstenHuhn

    VXworks corrupted with incomplete IP address of sw0

    Hi folks, here's what I entered (look screenshot). Still getting "Attaching network interface sw0... Error setting inet address of sw0 to 192.1681" Karstenhttps://files.engineering.com/getfile.aspx?folder=9b32d259-9f2a-49ac-80c6-9dc92b8f6813&file=Screenshot_2021-04-19_181739.jpg
  4. KarstenHuhn

    VXworks corrupted with incomplete IP address of sw0

    Already did this... c and cd command are the same aren't they. Anyhow, tried that and it still doesn't work. VXworks still carries on to insert 192.1681 as IP address for sw0.
  5. KarstenHuhn

    VXworks corrupted with incomplete IP address of sw0

    Hi guys, does anyone know how to correct a faulty ip address in VXworks? The boot parameters (c command) have been set properly but VXworks seems to retain fragments of a faulty IP address "in the belly" (see picture). -> "Attaching network interface sw0... Error setting inet address of sw0 to...
  6. KarstenHuhn

    Mitel 3100 Password Recovery

    Wow, thank you so much for your help, AH64Armament. I'm really happy with that. I downloaded everything so you can remove the link if you want. I'll keep you updated as soon as I have new information. Kind regards Karsten
  7. KarstenHuhn

    Mitel 3100 Password Recovery

    Thank you - I don't have a MOSS sheet - that's why I don't want to default it. But if you could provide SW anyway I'd be very happy - maybe I'll get access later. You can mail credentials for your dropbox to kasiwupp (at) yahoo.de Thanks a lot for your trouble. Regards Karsten
  8. KarstenHuhn

    Mitel 3100 Password Recovery

    Hi folks, I recently bought a MITEL 3100 from ebay just for fun. Login screen says 4.2.3.0_UK. Unfortunately, the default system/mnet login doesn't work (protected with an unknown PW). As it is also based on VXworks I tried a few commands known from the 3300 but they don't work either. Do...
  9. KarstenHuhn

    MiVoice Clustering & Resiliency

    Lundah, that wouldn't help - the settings are correct, they are all the same. Mitelboy, thanks for the hint, I will try that. Thanks, Karsten
  10. KarstenHuhn

    MiVoice Clustering & Resiliency

    Hi, did you resolve the problem? I actually got exactly the same. It appears when I try to start synchronizing a CXi controller with a vMCD (both MiVB7.2) Karsten
  11. KarstenHuhn

    SIP: 420 Bad Extension

    The problem is resolved: The flag "Require Reliable Provisional Responses on Outgoing Calls" was set to YES but had to be NO. Karsten
  12. KarstenHuhn

    5140 IP Appliance

    Hi guys, I got an old 5140 IP Appliance from ebay and connected it to a MiCollab w/ voice, vMCD 7.0 The phone works well, even the browser, but the keys personal directory, call logs, speed dials and voice mail lack functionality. When you press one of them the screen goes blank and the arrow...
  13. KarstenHuhn

    SIP: 420 Bad Extension

    That's the point, Billz66, I'm pretty sure to send the correct calling line information, I tried every variant. And yes, you're right, incoming calls are OK, outgoing are failing.
  14. KarstenHuhn

    SIP: 420 Bad Extension

    Hi guys, system (192.168.0.91) is a MiVB7.1 with Vodafone GER SIP trunk (formerly Arcor). The system uses no MBG and communicates directly with the gateway 192.168.0.1. All settings were done according to SIP COE Mitel with VF GER. The system registers and the SIP number can be called, both way...
  15. KarstenHuhn

    5550 / MiVB Console Call Queuing

    Thanks kwbMitel, I already assumed that :-( Karsten
  16. KarstenHuhn

    5550 / MiVB Console Call Queuing

    Hi guys, does anyone know if it is possible to queue a call on a busy station using 5550 IP console or MiVoice Business console? For example: an external caller A calls the console and wishes to talk to B. The console tries to transfer but B is busy. B HAS NO CAMPON! Standard behaviour: it is...
  17. KarstenHuhn

    Unable to dial * and # via QSIG in transit situation

    Hi guys, could anyone give me a hint with this situation: Mitel MCD 5.0 SP1 PR1 in a 3300 CXi box connected to an "upper" Siemens HiPath 3550 V9.0 (link is set as S2 ECMA QSIG Master). Everything fine so far but something seems to block * and # though they are in the middle of a dial string...
  18. KarstenHuhn

    Unable to dial * and # over QSIG-Trunk in transit situation

    Hi guys, could anyone give me a hint with this situation: Mitel MCD 5.0 SP1 PR1 in a 3300 CXi box connected to an "upper" Siemens HiPath 3550 V9.0 via ETSI QSIG PRI. Everything fine so far but something seems to block * and # though they are in the middle of a dial string. For example: I have...
  19. KarstenHuhn

    Cannot get rid of flashing DSS keys after changing Hot Desk numbers

    No, it didn't. But the solution is very simple. I just deleted the monitored devices in the Remote Busy Lamp Assignment form and re-programmed the DSS keys. That resolved the problem without the need of deleting the extension. Thanks for your assistance! Karsten
  20. KarstenHuhn

    Cannot get rid of flashing DSS keys after changing Hot Desk numbers

    Hi guys, platform type is 3300 ICP MXe, MCD4.0. We have personal ring groups with OP27 and 5340 IP telephone connected together under one number. The 5340 IPs are used for logging into Hot Desk profiles. Due to better optical busy signalling we swapped the DNs of OP27 and 5340 under each other...