Hi Folks I am back. Issue still persists. I ran wireshark on both the server and the clients for the same time period while I ran the display. There is definately some data not making it to the far end. My network technician is concerned about the large size of the UDP packets and the...
HI steeviedude,
My network guy grabbed some captures of the wire at both end and indicated no packet loss either way and latency less then 25ms. He did mention he is seeing ICMP timeout being sent from the client back to the server. The network tech seems to believe the packets are making it...
I when in to look at the the RTD Cache and the High Watermark for Unicast since last resart was only 16.
I doubled the default OAM timeout to 20000 ms and restarted the service but this did not seem to have an impact. I wtill have the same result. Successful on local client but still "No Data"...
Our vendor increased the max unicast sessions to 40 a couple weeks ago and that did nothing to resolve this issue. I would like to understand more clearly regarding the statement from the NTP "A separate unicast data stream is required for each unique unicast display on each client. The number...
MPLS bandwidth is not an issue. If it were we would have much bigger issues than inconsistant RTD. I have done some more investigation. It seems that the supervisor has done some customization to create these displays. He has multiple billboards created and then uses a Public Billboard...
Hi Folks,
I have a remote site connected via MPLS. We have a small call center group out there that uses the RTD from CCM 6.0. We use unicast to a desktop PC onsite that powers a 55" display. this has been in place and working well for years. The issue seems to be occuring when we launch...