This is a second MC32S card that I am adding. The original card is F000 all the time. The Signaling Server as been in service for about 5 years or more. Therefore the IP address on the Sig Server is not in conflict.
I am leaning to the port on the switch not being set up correctly.
Looking for some help. I have a VGMC card that keeps toggling back and forth from F000 to M000.
As anyone experenced this and are the able to help me resolve this. Not sure is this maybe a network issue or not.
Thanks
Hey folks
I am having an issue with a CS1000E site. Below is what is happening.
Both sets are NCOS 6
Start with the WORKING IP SET
1120E set calls Norway over SIP.
Calling 75562869
Call is getting a Ring No Answer
Now the NO WORKING TDM
3903 set calls Norway over SIP.
Calling 75562869...
Hi
I had this situation on the weekend and all is up now but wondering what the root cause might be.
Customer has 3 Analog cards in slot 6, 7, and 8 in Loop 0 shelf 1. There was no dial tone. Card in the other shelve worked fine.
The issue started as an analog line was not working. I disable...
Does anyone know if it is possible to to Play an announcement from the CallPilot of a PA system?
A customer wants to, In the case of an emergency be able to play a pre-recorded message over the PA system from the CallPilot.
They said that they were able to do this on their old Octel system.
Thanks Reusser
The MGC firmwire is up to date.
Also to my last comment about the audit conducted, the testing did not mention anything about the PRIs having any issues, therefore I beleive that it worked before.
I know we did some audit testing before this system went in to production back in december 2008. I don't remember us having these issues back then. I will go back and check the results.
Hey John, will we not have the same issue even if they are split? I mean the Call Server is down and when the other core comes up will the D channels still not act stupid?
Have and issue with a CS1000E HA 5.0.
Here is the situation. Call Server 0 is in building A and Call Server 1 in building B.
The ISDN setup it two physical T1 as one PRI with a primary D and backup D.
The T1 for building A is in l s c = 4 0 3 Loop 78 DCH 14 Primary with its own primary clock...
Hi Mike
Thanks, that is what I found out as well.
gwebster
You are right, I quoted the wrong bin name. I mixed up the letters. I was working on i2002 and i2004 as well. Bite mixed up there.
Thanks guys
I am having issues trying to upload the bin file toe the sig server. I select the bin file and press the button to start the upload and the hour glass spins and then stops. I checked to see if the file was uploaded and it does not show in the list. I uploaded a couple of other firmware bin file...
Would anyone hare a solution for the following issue.
I have a customer with a CallPilot 5.0 1005r HA system.
I recently changed the IP addresses for the CLAN, ELAN and managed IPs. This seemed to go fine, but when I try to bring the main Callpilot server back on line it gets down to the CP...
Here is what I got off Nortel site. I have 16 IP Users and No Basic IP Users.
Solution Detail
srpt214 Unable to add MGC to system after upgrade to 5.0w
--------------------------------------------------------------------------------
Problem Description
SRPT077 IPMG[8 0]: Loadware version...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.