I had this issue as well. tried all trouble shooting steps, but powering it off for a coffee break and then back on again, worked. Connected to the services port, I did a continous ping (ping 192.11.13.6 -t), waited about 10-15 rely pings then accessed the server using web. i also used ssh...
Here's more info...
Main CM Doc Page:
http://support.avaya.com/elmodocs2/comm_mgr/r4_0/avayadoc/03_300151_6/mainmenu.pdf
MG250/350 CLI Reference:
http://support.avaya.com/elmodocs2/comm_mgr/r4_0/avayadoc/03_300151_6/03_300437_3/03_300437_3.pdf
Later.
no question is ever stupid, but i've seen that before. yes, all three sites (main and 2 branches) have vcm cards set with appropriate channel settings per leg. i have the event scheduled for tonight. well update all after. thanks again for the excellant replies. it's great to know others...
Will also try Faststart parameter, but I read IPO Tech Tip 55: "VCM channels sometimes do not properly get allocated and de-allocated... Avaya recommends that Faststart be disabled.."
Looks like a Microsoft Update did me in. How can I changed the Configuration and Database share name/path from the application? I have no issue with the pbx, i just keep getting am "attempt failed because the character or file system name is invalid" error. Gracias.
All, Why would some calls from branch site(s) via an Small Community Network give "dead air' while being dialed?
I have a three component IP406 customer that is experiencing this issue. The customer has an ISDN-PRI circuit at the Main Site (IP406V1: 3.2(57)). Branch A (IP406V2: 3.2(57)) and...
Can someone assist me in finding the documentation concerning the network port connectivity requirements for using SCN? Basically, what ports (UDP, ect...) need to be open to allow all IP Office and adjunct communications... Thanks in advance.
I don't believe you will find the "official" statement from Avaya Support for the S-series servers. If you do happen to run across something, pass it on.
noidatech, check dcs notes and it looks like i had the incorrect min/max fields in the aar analysis table. changed the parameter to equal the udp code + internal digits dialed and it worked. thanks.
I'm trying to add a centralized vm to a new s8300/g350 (CM4.0.1) DCS site. I cannot add the rem-vm hunt group to the CM4.0.1. When I add the centralized vm ext int the 2nd page of the hunt group form, i get "extension must be an off-switch (UDP) extension". Troubleshooting, i find that i...
Change Protocol Version to "B" in the DS1 forms. This will keep the D-Channel up and Bring up the B-Channels. Also, make sure the primary and secondary are set correctly in the the sig form; Trunk set up should basically include the Trunk type as "ISDN-PRI". enjoy
I have a fresh install for bcmr 2.4 and have a problem initiating the BCMS Vu Server. I have a status dialog box which states "The service OmniNames.exe is not operating. This service is essential for ..." I have exhausted troubleshooting steps for this install, so I will do...