Has anyone ever connected their CS1K to a Brekeke server, and if so, how was it done, or where did you get the technical docs.
The vendor has already installed the Nurse Call responder V, and just now informing us that we need to connect to this.
I have limited info other than it is SIP, and...
we have a vendor that wants to connect the responder 5 (Brekeke server) to our CS1K. They are asking for an IP address of our switch, but can not narrow down which IP Address (OAI gateway, , node, sig servers, switch). Has anyone hooked this up and can you let me know exactly which IP address...
that is excellent information, thank you.
I have not had the ability to trace anything, most of the complaints are after the fact.
I couldnt log in quickly enough to trace anything.
great information though, and certainly some place to start.
thanks
Having some difficulty with IP Phones, where customers calling from TDM to IP will (not on demand) leave the current call path, and end up on another conversation (call path) where the other call path involves an IP Phone also. Seems to me that something is happening to the MC32s and it is...
Does anyone know of a really good call accounting software.
We used to have a system called Tru Systems, but can no longer find them online.
Like anyone else, we would need instant access to call accounting details. Obviously for a CS1K
The system that we have now is basically junk. really...
just checked again and those cards are the correct vintage.
I am leaning towards the clocks or cabling as well.
Avaya is the one directing our maint contractor to replace the cage, but I dont think that they are aware that the clkc has issues as well. time to update the ticket.
we do. we have checked everything from the vintage to the dip switch settings, and everything is on track.
we stat'd the clocks and have found no issues.
We are not sure exactly what caused it. last year we upgraded from 5 to 6 on the switch.. a few days later we started receiving FIJI errors. our vendor began swapping out things from there and unfortunatly we have so much going on that this issue became idle until now.
I hope it doesnt come to that. Thanks for the information. we tested the working FIJIs from other shelves with no success. Even brought in 3 new ones (also looked for bent pins on the back plane, but those are hard to define).
since everything is dependant on everything around it, it is like...
we did replace the per sig and the 3PE, but found nothing. the vendor seems to think it is the back plane, but that is a really invasive procedure for a hospital to endure, to replace a cage.
I thought about a 3 part approach, new ntrc49, new clkc, new cage.
I just wanted to see if anyone...
we have a FIJI that will not operate on the 1-1 shelf, but operates on other shelves.
we had another facility repalaced their CLKC and their FIJI loaded the firmware and they were able to join the ring. we tried that and lost all of our PRIs, and the CLKC 1 (standby) had both the red and...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.