Hi, bob,
when i say "won't start correctly" i mean that when i plug definity to power,red led of procesors card blinks, then turn into yellow and after some time again turns to red.
"Old memeory card was dead" - as symptoms writen above it's obviously problem with memory card. I even cannot...
Hello everyone,
i have old definity system, the problem is that old memory card was dead when system was restarted. Now i got another memory card, but when i plug it, system won't start correctly. What process should I do now to get beck it work?
Hello everyone,
maybe anyone knows how should be connected TN2185B board and external ISDN device? Official Avaya documentation said, that first port on board TN2185B are on pins 26, 1, 27 and 2. They named as "Term transmit Tip", "Term Transmit Ring", "Port transmit Tip" and "Port transmit...
Hello everyone,
I have the situation here. I have Voicemail Pro (6.1), IPO (6,018) and all I need is to create some short code, that i could dial and change Auto attendant (between two AA). I found info with some example in official Avaya document "Voicemail Pro Example Excercises", but it...
Hi everyone, maybe anybody have possibility to check or knows are the new Avaya 1408 digital phones works with old CM4 system? And how about the other types: 1408 and 1416? Fully functioning and call log works fine?
Thanks in advance.
Hi,
I've got problem with registering Linksys endpoint. I have another SIP endpoint phone and don't have any problems, but with Linksys... Maybe i missed something, don't know. It wont register. All I do is enter these parameters:
[Ext 1] tab:
Proxy: IPO IP
Display name: name of sip endpoint...
Hello,
I have IP Office 403, VM Pro PC and License USB serial key. Everything works until VM Pro PC broken down. Now I'm moving into another PC. Installed VM Pro and Feature Key server. Plugged in USB serial key. Feature Key Server detected USB Serial Key (Icon turns to red). Configured IPO...
Hi,
I have one problem - we are connected phones to PBX, that PBX connected with G430 through BRI, and that G430 connected to main call server through IP. Everything works, but there are one problem - voice are very silent. Maybe anyone have any idea how to make it louder?
Main server version...
Looks like I've got the solution for this problem. It seems that one of the providers ISDN's was not working properly. Sometimes it was working, sometimes it's not. After when they changes both boxes, looks like everything work as it should. Thanks everyone for the responses!
Hi everyone,
maybe you'll have an idea how to solve my problem. There is old IPO v401. two ISDN's BRI are connected. Both ISDN's are configured as one pool (line id: 0). The problem is when any one call from outside to main number (for example: 201), the call are excepted and begins to talk to...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.