yes Triton , when i turn off the health monitor it is work , but in one direction from CS to BCM , but not working from BCM to CS !!! Any suggestion will apreciate.
other question : when I have to use the helth monitor ??
( I still can`t ping the GATWAY`S , is it response just when we...
i work in a lab environment , iam wondering that pabx running as standalon , ip telephone work will.
what u think about physical connectivity ,all hardware infront me on the lab table. already i setup the g/w and routing.
i think i have some wrong on the network routoeing , so need help if...
I`ve already configured PBX RLS 5.0 wih h323 voip trunks.
All TLAN & ELAN IP are reeacheble except the gateway for BOTH TLAN & ELAN are not pingibb.
when running the maintinance report in element manager for VTRK , the result is , VTRK status :standby ,
reason due to the network failure...
John : did you dial AC1 ? AND JUST ac1 APPEAR ON cdr ?
this is what programmed on the system :
CDR_DATA
CDR YES
IMPH NO
OMPH NO
AXID YES
TRCR YES
CDPR NO
ECDR YES
BDI YES
OTCR NO
PORT 2
CNI DGTS
BCAP NO
(system is option 11 rls 4.5)
have programmed 3 roots with ACOD as folowing :488 , 489,490 . Programmed the ESN , SPN and using 9 as AC1 .
Customer just dail 9 to get access to the roots .
and he is bothering that in cdr the ACOD (488,489,490 ) is appearing befor the dialed digits , he...
Dear friends
First I am sorry for r late in replaying , because now a days just on evening have access to the internet.
Second, I want you to have the idea that I did not configure the NCTL or FCR , is that effect ??? Despite the phone with UNR??
TYPE RDB
CUST 00
ROUT 5
DES H323
TKTP TIE...
This is our first RLS 5 pbx, i checked the tgar and other resriction , every thing is ok, but regarding johonpoole question , iam not configure the nctl or fcr, do u think think that is the reason??
has system rls 5 with cppm ss. with h323 vtrk & pri ,when i dial the acod for h323 rout or the PRI i get busy tone and get the message on phone wich sayes release destination is busy ,ring again . ( no any restriction)
do you think that the ss need pathes ? and if yes what kind of batches ...
have one MG rls 5 , slot 1 cppm, slot cppm ss, wnat to put PRI card on slot 4, i programed in ld 17 the pri as 12, a the MG_CARD 0 0 4:
PRI2 MG_CARD
012 000 0 04
My qustion is : what is the TN must be to define the service channels ?
just now i start configure rls 5 pbx, i`ve already created the DDB. but when try to print it to see it i got that error, when try to to add it as :
REQ new
TYPE ddb
SCH203 MEAN : SCH2031
Digital data block already exists.
Iam no configure yet PRI or DTI .
any expalnation why when try to print DDB in ld 73 , i get :
EQ prt
TYPE ddb
SCH3558
SCH3558
SCD DB LD 73 - No DTI threshold set defined.
what that mean?
regards
yes acewarlock, i know that , but when i want to continue with writing 2008 i get this message , and can`t complete it. need expalanation for this : ERR193 Invalid NTP table
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.