Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. telecoman

    Siemens DX Messenger Programming

    Hi there all, I have here a Siemens DX Messenger card. When I dial the Messenger via the hunt group or a port I receive the reply "Your call is being transferred to the operator". I would like to change this to the message "Welcome to the Messenger System - please enter extension number...
  2. telecoman

    Upgrading RISC CPU cards

    Hi all, I'm still having problems with this one! I've changed the two 40-pin EPROM's on a 871/1/06796/010 CPU card to those from a 871/1/06796/011 CPU (BA687 on 010 & BA804 on 011) and tested the card in an iSDX-S but still get the red LED on the UPI indicating software error! Is there anything...
  3. telecoman

    Older iSDX - L RISC CPU Cards

    Hi all, I'm still having problems with this one! I've changed the two 40-pin EPROM's on a 871/1/06796/010 CPU card to those from a 871/1/06796/011 CPU and tested the card in an iSDX-S but still get the red LED on the UPI indicating software error! Is there anything else that I need to do eg:-...
  4. telecoman

    Older iSDX - L RISC CPU Cards

    Hello pablo100, First of all I would like to say a big thank you for your very useful help. It seems as though I was on the right lines in trying the newer firmware from a 1HAC 50104 AAJ, just that it was the wrong firmware. I take it that the same correct firmware will suit any of the 871/1...
  5. telecoman

    Older iSDX - L RISC CPU Cards

    Hi all, Does anyone out there know the differences between the older RISC CPU cards 871/1/06796/00x normally running on 5.2 software and the newer RISC CPU cards 1HAC 50104 AAJ normally running on say 6.1 software? The Rev. 6.1 Electronic Publication implies that the older CPU card can be set...
  6. telecoman

    Siemens Optiset E Memory Telephone

    Hi dark5tar and Pablo100, Thank you for your input to this. I thought this would be the case, just needed confirmation. I'll put it down to being part of the learning curve! I still think it rather strange that all of the other phones in the Optiset range work on the Realitis/HiPath DX though I...
  7. telecoman

    Siemens Optiset E Memory Telephone

    Hi there everyone, I have here a Siemens Optiset E Memory telephone in first class physical condition. However, on connecting the phone to my Siemens Realitis DX (slightly older version of HiPath DX), the header "Optiset E Memory" appears on the screen but nothing else, no dial tone, etc. My...
  8. telecoman

    Siemens DX Messenger E-mail facility

    Hello all, I have a Siemens DX Messenger card with the E-mail interface. I've set the appropriate IP address on the Messenger card to that of the computer running the E-mail interface programme. When I try to set up the E-mail interface programme on that same computer, it rejects my set up as...
  9. telecoman

    Realitis DX Route Restriction

    Hi Happymal, Thank you very much for your very quick reply. I am really after 24hr. route restriction, rather than TOD route restriction. However, activating the TOD feature, route restriction still did not work. I then checked LACA and found that least cost routing was activated. I...
  10. telecoman

    Realitis DX Route Restriction

    Hello all, I am installing a second user Realitis DX running Issue 6.1 software. Try as I may, I can't get the route restriction to work. The time of day route restriction feature is turned off. The trunk group access for exchange trunks is turned on and the appropriate route restriction...
  11. telecoman

    Siemens Realitis Voicemail

    Hi everyone, I wonder if anyone can help me with a second user Realitis Voicemail card 1HAC 50089ABC (not DX Messenger)? I have recently bought this card and wish to tailor it to my own requirements. Unfortunately, I can't get into the software to do this as a password is required which has...
  12. telecoman

    Old iSDX Colour

    Hi Pablo100, Thank you for your reply. Halfords have their own grey primer in single very small touch up bottles with a tiny brush but having tried it, this is much too light. I would have thought that Halfords own grey primer in spray cans was the same shade as the touch up bottles. Thanks...
  13. telecoman

    External Voicemail

    Hi Joe, I bow to DXcomms greater experience on this as I haven't actually set this up myself. Are your extension cards 1HAB 50060 or 1HAB 50083? These cards have a link selectable Message Waiting facility. If the extension cards are 1HAB 50010 or 1HAC 50049 then Message Waiting is not a...
  14. telecoman

    External Voicemail

    Hi JoeHawkins, I've read your post and first of all I must say that there is no such System Parameter as SPWMI. I assume that this is probably a typing error and you mean SPMWI? SPMWI has only two allowed values, 0 and 1. Message waiting indication given by the system. (0 = No, 1 = Yes -...
  15. telecoman

    Realitis DX Trunk Main Groups

    Hi all, I am installing a second user Realitis DX running 6.1 software. I wish to delete some of the old trunk main groups, but on using DTMG, I keep getting the error message "Group has trunks". Using "LTK m group no." does not show any trunks associated with these groups. I have used LTTA...
  16. telecoman

    Old iSDX Colour

    Hi there all, I have an old iSDX switch built in 1991. The main cabinet is a dark grey crackle finish. I would like to touch up some of the marks on it and wondered if anyone out there knows exactly the name of this dark grey colour and where paint might be obtained from, please? Any help...
  17. telecoman

    Interfacing Realitis DX with Seltek Voice Manager PC.

    Hi both, Thanks for your help - greatly appreciated. Yes, CIL is present - what speed does it need to be? - presently set at 1200 Baud on the Realitis. I am mainly interested in how to set the Seltek software to suit the Siemens switch. Very best regards, Telecoman.
  18. telecoman

    Interfacing Realitis DX with Seltek Voice Manager PC.

    Hello All, Does anyone out there know how to connect a Realitis DX or iSDX to a Seltek Voice Manager PC running 4.7 software, please? The Seltek Voice Manager 4.7 Manual says that the Seltek is compatible with Siemens but does not give any further guidance. As always, any help is greatly...
  19. telecoman

    Siemens DX Messenger Card

    Hi all, I have a Siemens DX Messenger Voicemail card 1HAC 50145 fitted to a Realitis DX switch. I've managed by absolutely sheer good luck to discover the "Log In" name and the "Security Code" for System Administration on the card. However, that good luck doesn't extend to finding the "Log...
  20. telecoman

    Software Password Encryption

    Hi there all, Does anyone out there know anything about the encryption algorithm used to encrypt the passwords in software issue 7.1? I have looked at this myself and have found repeating patterns, embedded text and certain multiplying factors but haven't as yet discovered how the encryption...

Part and Inventory Search

Back
Top