Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. sarakodi

    Embedded Voice Mail Issue

    Folk's I have a customer that wants to check several mailboxes remotely,however she has to hang up and call back into voice mail to check the other mailboxes. Is there a way to check multiple mailboxes without having to hang-up and call back? Thanks in advance
  2. sarakodi

    O/32 Dropped Calls

    Thanks Think I'm going to have customer order 1 line from Verizon install it and have them use it along with Optimum, Then we'll know for sure I'm done fighting Optimum
  3. sarakodi

    O/32 Dropped Calls

    Ok here's my situation I have replaced everything from the 0/32 cabinet to the amphenol cable for the trunks, an older vintage trunk card. line voltage is 50volts DC and Optimum has replaced there cable modem device. Yet the problem still excists Let me update all on the problem recieve a call...
  4. sarakodi

    O/32 Dropped Calls

    I took my volt meter and found 50volts DC across Tip & Ring and off hook it went to 9volts. I didn't think to check for ring voltage even though I've had a similar problem like this with VOIP lines and voltage. Could I make any changes in the norstar line programing?
  5. sarakodi

    O/32 Dropped Calls

    Call comes into Norstar and intermittently the call drops during mid conversation, light goes out on phone but caller still there, we seize the line again and continue conversation. New install, Cable modem, Optimum, swapped out to an older vintage trunk card,and problem still excists. Thanks in...
  6. sarakodi

    OPT 11 to Cisco don't have QSIG

    Thats exactly what its going to come to.
  7. sarakodi

    OPT 11 to Cisco don't have QSIG

    Didn't help still can't call between Nortel & Cisco and it's getting old real quick because I seem to be making all the changes yet the problem still exsists and the vendor installing the Cisco side keeps saying he's set up correctly yet I don't know enough about the Cisco to say he's wrong.
  8. sarakodi

    OPT 11 to Cisco don't have QSIG

    RickyPone (TechnicalUser) 1 Nov 11 12:32 TIE route for me. I know that they say ni2 interface will work and it probably will. I bet something in the gateway needs to be changed. I saved the email from the cisco tech that stated what he changed. I'll look for it. Rick any luck locating...
  9. sarakodi

    OPT 11 to Cisco don't have QSIG

    Rick The four PRI's where they set as TIE or DID? I'm having lots of luck with NI2 DID internal Cisco to Nortel are good and Nortel to Cisco are good, I just cant get an external call to the Cisco and can't Make external calls from Cisco out of the Nortel, calls end up @ reception phone. What do...
  10. sarakodi

    OPT 11 to Cisco don't have QSIG

    Ok latest update seems that the call is making it to the Cisco phone it flashes and the phone rings for a brief audible signal and thats it. moment and thats it. I get a busy signal on my end. Any Ideas ???
  11. sarakodi

    OPT 11 to Cisco don't have QSIG

    Changed it to TIE made call from 914-227-6815 to Nortel did 203-422-7846 that CDP's to Cisco ended up reception after hour’s menu. DCH Message: PRI228 DCH: 6 DATA: 00000000 DCH 6 OMSG RELEASE REF 00000003 CH 0 TOD 14:42:14 CAUSE :MANDATORY INFO IE MISSING DCH 6 IMSG UNKNOWN REF 00000000...
  12. sarakodi

    OPT 11 to Cisco don't have QSIG

    Trying to set up PRI between Nortel Opt11 and Cisco Set up is NI2 trunk type is DID can call back and forth but unable to call out from Cisco and Cisco can't recieve external call from Nortel, calls revert to operator I don't have QSIG Thanks in advance Mike TYPE adan dch 6 ADAN DCH 6...
  13. sarakodi

    Global Changes using OTM

    I'm attempting to make a global change in OTM to a large amount of 500 sets. I want to change the CLS of these sets to MNL and I want to set the FTR to HOT D 4 5200 Thanks in advance Mike MIke
  14. sarakodi

    Callpilot 150 outbound transfer issue.

    I have a CCR tree built with option 1 to transfer to external number I have tried selecting a line pool and a specific line but does not transfer I get the following message from the callpilot. (The configuration for this call is not valid) I get this after watching the callpilot seize the line...
  15. sarakodi

    T7406e handsets

    I'm looking to install two T7406e cordless phones on a compact ICS and was wondering if I can get away with one base station for two handsets? Thanks In advance Mike
  16. sarakodi

    Trying to use the INT treatment to redirect calls?

    John Poole I did what you told me however the calls still go to the attendant. This is how I set it up for NBLK NBLK----> OVF OVF OVF RAN RAN 20-----> This RAN is already recorded for something else. What do you think am I missing something Thanks Mike
  17. sarakodi

    Trying to use the INT treatment to redirect calls?

    I’m trying to figure out a way to utilize the intercept treatment in LD 15 to redirect external calls for an extension who’s CLS is set to FR1 which under normal conditions are directed to the operator. I would prefer it go to a RAN or even better to the voice mail system. Anybody have a clue...
  18. sarakodi

    TMDI Install

    Thanks SSJVirus007 I think thats what I need
  19. sarakodi

    TMDI Install

    I'm not using a DB15 I'm going to connect a 25 pair cable to the port I'm installing the TMDI card into and then I'm planning on punching down the 25 pair cable and cross connect a patch cord just to get the circuit up and running until we get the correct cable.

Part and Inventory Search

Back
Top