Hi SBCSU,
Thank you for your replies, especially for the CAT info, it was important not to loose so much time.
Finally I had in my hands the Cordless Service Manual and the CAT, and as I expected, no need for the CAT to see the Cordless Pins, since everything is record in SLC card, just have...
Thank you Donb01 for your reply,
At the same room there is a identical phone working, and my colleage tried to register the another phone and we got the same response from the phone ... probably invalid pin.
Where can I check the PIN?
I leave some more infos about the set...
Hi there,
I guess it's a noobie question, but the cordless system it's still a bit foggy...
I have a Gigaset S4, that was working and suddenly lost registration, it shows something like "no basestation", and it appears on the screen the extension number and the strenght of the radio signal...
Hi there,
Just to leave a note for someone who comes across with something similar.
First thing, to the "old M1" guys, the HMS400 it's an external server based on W2003S, with a digital board (Dialogic) to connect to the DLC on M1, Has nothing to do with the Meridian Mail, (and Nortel). It has...
Ok guys,
Thank you for your answers, it's working, apart from the first "bug" of leaving the out and inc group id by default, which cause the blockage of outgoing calls, the rest was a common error "invalid user", with the tech on site with the TREND it worked, just the patching was on the...
Hi,
Yes, I set both to 30, but I guess the initial problem was that it was set by default "0", cause now I have just sent the same cfg, and atleast in my softphone i can do calls, I'll see tomorrow morning (here it's 22) if everything is working.
One last question, cause I am trying to...
Thank you for your answer,
Yes, it's when I set to S-BUS and save, and after the reboot, the users can't use the other BRI (T0).
The lights I cannot see them, I am doing it remotely and out of working hours, so no one to check that.
I am asking in case it's something very basic like the one...
Hi there,
Can somebody give me a hit, I am setting up a BRI S0 from a DaugtherB 2BRI in IPO500V2 R8.1, to connect a PC ISDN board, and when it reboots it's not possible to do external calls, which is on the other DB card 2BRI.
It's connected with a cross cable and with the 100ohms at both...
Hi,
Just check if the disk starts (you can feel the vibration and the noise) and check the AML on LD48 and the AX tty , disable and enable both. Make sure the TTY port(hardware) for AML is ok, or it won't send the ID (FOX) and it gets stuck there...as far as I remember long long time ago.
I...
Once again
Thank you all.
I will setup and test the connection between the IPO in NT mode and Avaya(Nortel) TE mode, and later with a Siemens TE mode, then I will post the results.
Best regards
JMF
Thank you amriddle,
Sorry but I am a new in IPO500 world, in fact I have our lab system now to startup.
Some more doubts:
- does any BRI card supports the S-Bus configuration,as you mention, including the comboBRI card?
- Do I need to have a special NT (ISDN Network Terminator)or a common one...
Hi all
Thanks for the quick reply, GHTROUT , your sugestion did the job, I did the test and it works ??!?!? but I am confused ... by the NTP
(DNDD) Dialed Name Display Denied
DNDA Dialed Name Display Allowed
after all this time, always find some funny ones like this one, and thinking that...
Hi all,
Is this a BUG or is like this and it always has been like this. - already check on 3 different sites and releases and they all do the same. (rls 22.46, 25.40b, 04.50w)
When I dial the night service DN, it shows the originate DN and name as usual.
When the ATT is set to night service...
Hi all,
Here is something that i really need some help(and I have lots of ***** to give), after reading all the NPTs and testing for 2 weeks, I still cannot make this work, and the worse is that with other "small" systems it's possible to do it.
I need to implement the following scenario:
- a...
Hi all,
I've testing a message waiting lamp on a analogue set with ATA2 - BCM50B 4.0 , but no luck, not even tone ...
Does anyone tried or know if it works?
thanks
Hi all,
I've testing a message waiting lamp on a analogue set with ATA2 - BCM50B 4.0 , but no luck, not even tone ...
Does anyone tried or know if it's suppose to work.
thanks
Yes,
isdn (BRI)basic rate interface has some terminals (TE), like isdn phones, fax G4, isdn 64k PC board for data, videoconference, etc.
So "any" isdn phone will do, to tests your dsl.
If the wiring is correct and the equipments are with power,
Layer1 (L1-physical) should be UP, layer2(L2- data...
Yeap
That's what I did. thanks and sorry I forgot to mention.
There was some tasks stopped but nothing special.
Deplst 02 - core is in service, but no swap.
About the IP address it's set with the default IP, and both LAN are connected, LAN2 with across cable between the two CPU cppiv
I am...
Hi Nortel23
Do the L2 get UP too?
I guess you don't have any ISDN phone to test the DSL one by one.
What you can do is to set a internal(DN) call (but only voice call) from the Tandberg , change setting for voice calls only, before you try Videoconf call.
Check the status of the dsl, you can...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.