Thanks for your replies Cluebird & VinceWhirlwind
@ Cluebird : Yes I believe that the timeout is on the higher layer associated with authentication and currently I found that there is a firewall existed between the two machines(Kaspersky firewall). But we already changed all the idle timeout...
Thanks for your reply Cluebird
What I meant is that. Currently we have two machines connected through the switch. Let's say machine A and machine B
The application installed on machine A used port 1234(random port) to connected to machine B 's port 5100(The port that we preset-ed as the...
Hi I am still encountering problem with this issue,
I want to ask if anyone know if there is any default timeout value set for this switch even if the sysauthcontrol is disabled ??
Thanks
Ben
Hi all,
We are current using the Cisco 3750 switch. We have disabled the sysauthcontrol as shown below:
CoreHoiso1#show dot1x all
Sysauthcontrol Disabled
Dot1x Protocol Version 2
Critical Recovery Delay 100
Critical EAPOL Disabled
However, we found...