Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: reimm
  • Order by date
  1. reimm

    Directory Number Error

    Hi to all, Anyone knows what causes Directory Number Error in BP250 system? It seems that the third operator number Dir 202 is Vacant when dialed. While the other 2 operator numbers is working okay. Thanks.
  2. reimm

    halt shutdown on mx-one server

    Hi himdp, Thanks for the information.
  3. reimm

    halt shutdown on mx-one server

    Thanks for the reply. What will happen after boot after shutdown of servers by the command shutdown -h now @ su? Thanks!
  4. reimm

    halt shutdown on mx-one server

    My target is to start the server automatically from the latest data_backup made. Like starting it when command @ root: shutdown -now is initiated.
  5. reimm

    halt shutdown on mx-one server

    If the server had been stopped already and shutdown...what other else can be done?thanks
  6. reimm

    halt shutdown on mx-one server

    Hi himdp, Thanks for the quick response.is it on start up of the server will i command init 2?
  7. reimm

    halt shutdown on mx-one server

    Hi to all, Can anyone know how to cancel halt shutdown of servers...@ su: command shutdown -h now,,,how to cancel this command. Thanks in advance.
  8. reimm

    fault code 65?

    Hi CDIV, Thanks for the reply. Here is the result of SCEXP & GJTSP command. The system has only 1 LIM. Best regards. <SCEXP; EXTERNAL SYNC RECEIVING LINES DATA MASTER LIM STATUS [MASTER SCOPE] FIRST CHOICE 1-0-00-0 SYNC RECEIVING...
  9. reimm

    fault code 65?

    Hi to all, I have this fault in TSW fault code 65, can anyone know how to solve this fault? Thanks. CLASS: 3 65 SYNCHRONIZATION FAULT IN LIM DATE TIME ALP NOIF EQU INF2 INF3 17FEB16 16:51:06 1 1 001-*-**-** 2 1 LAST ALREI: 17FEB16, 16:51:06 END
  10. reimm

    Dial tone

    When initiating data_backup it does not continue.. MDSH> data_backup Change of market data is not complete. Start and restart of the system is needed. What should be done to make data_backup successful? Thanks.
  11. reimm

    Dial tone

    Thanks whosrdaddy for the reply...after market_set is initiated, is start and restart of the system necessary? will this restart affect the system ongoing calls? Thanks.
  12. reimm

    Dial tone

    Hi all, After reinstalling server 1 & server 2 on mx-one TSE 3.2 all was working okay, except that the DIAL TONE was different compared to the dial tone before the re-installation. All extensions (ANA, DIG, IP) on both server 1 and server 2 have this different kind of tone. Can anyone know if...
  13. reimm

    CIL not working

    Hi xs, Thanks for the response. I'll try to warmstart first the system.
  14. reimm

    CIL not working

    Hi all, Need help for the problem in BP250 CIL. it suddenly stops transmitting call log data. Actions have taken are checking connection cable(ok), tried using other port in CPU-D5 (still not transmitting CIL}, re-program CIL, activate ports, changing COM PORTS settings. (9600,7,Even,1,None)...
  15. reimm

    bp250 can't sent post dialling-digits after an Announcement is heard

    Hi to all, Can any one know what I am missing in the config/parameter of bp250 in which it can't sent post dialling-digits after an Announcement is heard. e.g.when bp250 dial external calls, after voice announcement is heard on the called line when digit is pressed there is no response. Thanks...
  16. reimm

    MD Disktool not responding

    Thanks for the reply..problem been solved.. it seems there is fault in NIU, since after made restart I can now connect using MD Disktool.
  17. reimm

    MD Disktool not responding

    FAS 102 70-R3/2 SAM 6.2
  18. reimm

    MD Disktool not responding

    Hi to all, I have encountered a problem using MD Disktool, it does not respond after tried to establish connection. OS of my PC is Windows 8.1, 64bits. I tried deactivate/activate Windows Firewall & AVG Firewall still problem occurs. I wonder if Firewall prevents it from connecting. Thanks in...
  19. reimm

    LCR tone in BP250

    Thanks.
  20. reimm

    LCR tone in BP250

    Hi, System is BP250, can anyone know changing LCR tone to a normal dial tone? Thanks in advance. bR, reimm

Part and Inventory Search

Back
Top