Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Thomas VIII

    NEC SV8100 Operator issue

    47-08 is not being used that I know of. Is there config options for mailbox 1? This is the one I presume is being used.
  2. Thomas VIII

    NEC SV8100 Operator issue

    I have a SV8100 where the auto attendant picks up and the user presses 0 but the call is not going to the operator ext 321. 47-13 is defined as Unscreened transfer to 321 on 0. One odd thing, if a caller presses 4 it comes back as I did not recogonize that command, then plays the greeting...
  3. Thomas VIII

    Rebooting a BCM 400 4.0 / BCM 450

    Not sure if the problem is something inside the BCM, but I cannot connect using Element Manager unless somebody on site reboots the BCM. I can, however, get to the main splash page going to the web page 10.xxx.xxx.xxx. Just thought there was a command using PuTTy to force a remote reboot.
  4. Thomas VIII

    Rebooting a BCM 400 4.0 / BCM 450

    I know with a BCM 400 ver 3.7 or earlier you are able to perform a reboot remotely. Is there any way to reboot a BCM 400 ver 4.0 or 450 remotely if you have access to the main splash page?
  5. Thomas VIII

    Element Manager

    I have a weird one. We have a customer with multiple BCMs though out the network at different locations. I can put in the IP address and hit the web splash page but won't connect via element manager. Its not until we reboot the BCM that I can connect, then this will last about a day or so then...
  6. Thomas VIII

    NEC Mark ii

    I have a system with a bad ECR-E card. I am having a hard time trying to find another one. Does anyone have any suggestions? I am trying to get a night ringer going. I though of using a SLI card and program the analog port to ring in night mode but I found out you cannot program the single line...
  7. Thomas VIII

    Call Pilot on a MICS

    I have a customer that has a MICS 6.1 with a call pilot. Calls come in and table 1 plays a greeting and the caller presses 0 to talk to someone. The call is transferred to a hunt group (broadcast) on 4 phones. If the call is not answered within 4 rings, we get a "The operator is not available"...
  8. Thomas VIII

    BCM 400 ver 4.0 hard drive replacement

    Youcef31 Its hard to say. I order the hard drive from a 3rd party. The description says its a 4.0 BCM hard drive so I can presume they load a image on it before it leaves. I never see the drive, it goes straight to the site. My guess is that after its installed and if the services come up with...
  9. Thomas VIII

    BCM 400 ver 4.0 hard drive replacement

    I researched this and think I found the answer. Once the new hard drive is installed, need to wait 20 min After 20 min, log in with Element Manager directly thru the laptop on default IP 10.10.10.1 on LAN 1 username nnadmin password PlsChgMe! Change the time, date, and time zone Change the IP...
  10. Thomas VIII

    BCM 400 ver 4.0 hard drive replacement

    How do you initialize the hard drive thru the serial port on a 4.0?
  11. Thomas VIII

    BCM 400 ver 4.0 hard drive replacement

    I now have tried 2 hard drives and both have failed. I have a corrupted hard drive in a BCM and replaced the hard drive with one that is imaged to a 4.0. Power down the BCM and installed the new hard drive. System comes back up and works and the Nortel services are up and functioning. All solid...
  12. Thomas VIII

    SV8100 License issue

    When trying to access 90-37-01 it will not take that address. I did see 90-55 Free License select is unchecked. Should that be checked?
  13. Thomas VIII

    SV8100 License issue

    What if this software is lower than 5000?
  14. Thomas VIII

    SV8100 License issue

    I can download the database through PCPRO but cannot upload. I get this error when I log in "the system doesn't have enough license (256 port max port license) to accommodate this PCPro data" Is there a way to fix this or a temp fix?
  15. Thomas VIII

    Tech support for NEC systems

    mbrathod8285 how do I contact you?
  16. Thomas VIII

    Tech support for NEC systems

    That company will not work on SV8100s. Any other ones you have in mind?
  17. Thomas VIII

    Tech support for NEC systems

    Does anyone recommend a company for tech support for NEC SV8100 systems? Something that can be done with a tech on site over the phone?
  18. Thomas VIII

    SV8100 DND question

    I have a couple of DIDs on a SV8100 that is not ringing the analog sets its programmed on. At first, I thought maybe the sets are in DND and had them try picking up the handset and dialing 7470 but they only get a busy signal when trying that. In 22-11 The received number is correct and the...
  19. Thomas VIII

    SV8100 Call forwarding at night

    So it turns out the phone number I need to forward from is a DID number off of a PRI. Currently, the number is pointing to a VN in the system. I am not sure where to go with this now. There is no actual trunk port to use. The DID with the correct received number is pointing to 4303 VN. In...
  20. Thomas VIII

    SV8100 Call forwarding at night

    Thanks belevedere. I will try this. Is there any way to get you the. .pcp backup of this program to you to see how they currently have it? They way i read it, they use a virtual ext forwarded to the cell phone but the main number goes to a the auto attendant. I'm not quite sure though.

Part and Inventory Search

Back
Top